13
●
Return to Current Numbering
If operators would like to return to the current numbering, the system administrator should turn off the global cam-
era numbering select check box in the WV-ASC970 Admin Console CPU screen.
■
Alarm Programming and Handling
●
Program the Alarm
This function allows administrators to program alarms, assign alarm display targets, and define alarm actions.
●
Control Alarm
Alarm controls are operator functions. These functions allow the highest priority operator to seize the alarm and
control it. These functions also allow the next highest priority operator to gain control after the highest priority oper-
ator releases the alarm.
The alarm controls include:
• Arm and disarm alarms
• Acknowledge active alarms
• Reset acknowledged or active alarms
The system also supports automatically resetting and acknowledging alarms through configuration by the Admin
Console.
●
Alarm Action
The system supports the following alarm actions:
• Camera spots (both local and global)
• Tour sequences (both local and global)
• Group sequence
• Text display (Only WJ-SX650 or WJ-SX850 switch node)
The system supports up to 10 alarm actions, and allows operators to control acknowledged alarm actions.
Note:
• The system can handle up to 64 alarms at the same time. In case of more than 64 alarms, some delay happens
before alarm actions.
• If a higher priority operator seize the alarm target monitor, the alarm action is not executed. In this case, the tar
-
get monitor connected to WJ-GXD400 shows red frame, while the monitor connected to WJ-SX650 or WX850
blinks OSD texts.