47
Monitor Display Control
Number of characters displayed on the monitor screen
differs depending on systems.
•
GX System (NTSC model only), System850:
40 x
16 characters
•
WJ-SX650 512 x 64 Full Matrix System:
38 x 14
characters
The following are examples of WJ-SX650 512 x 64 Full
Matrix System monitor display.
■
On-Screen Display Control
The procedure described below lets you determine the
display, such as camera title, clock and status, on and
off on the active monitor screen.
1. Select the desired monitor. (Refer to p. 39 Monitor
Selection.)
2. Press the OSD button. The OSD items (camera ID,
monitor status, and general status) will be hidden
from the monitor.
OSD Example
Cxxxxx:
camera number
Mxxxx:
monitor number
axx:
area number
Sxx:
controller number with super user privilege
operator
Kxx:
controller number with normal user privi-
lege operator
Txxx:
Tour Sequence number
R:
Run
P:
Pause
ALM:
alarm occurring
MON OSDAll Off CAM
0123 Unit:01 00512
07/07/1999 03:37:21 PM
M
■ ■ ■ ■ ■
a1 ALM T
■ ■ ■
R A
■ ■ ■
C
■ ■ ■ ■ ■
CAMERA TITLE
Clock
General status
Monitor status
Camera ID
Axx:
alarm number
-0 to -9
alarm action number
∗
:
alarms behind
Playback on WJ-GXD400
Pause on WJ-GXD400
2
3
4
5
6
7
FWD on
WJ-GXD400
2
3
4
5
6
7
REW on
WJ-GXD400
Record end
Note:
• Every time you press the OSD button, the OSD
items will be displayed or hidden. When the OSD
items are displayed, the LCD display will become
as follows.
• You cannot display or hide the clock (time and
date) by pressing the OSD button. Refer to p. 55
OSD Control.
• To display or hide each OSD item individually, refer
to p. 55 OSD Control.
• Only WJ-SX650 and WJ-SX850 switch node sup
-
port for control the clock and general status.
• When the playback continued at
5
/
5
(rotated
the shuttle ring to the end) for 5 seconds, the play-
back speed indicator will change to
6
/
6
. When
the playback continued at
6
/
6
for 5 seconds,
the playback speed indicator will change to
7
/
7
.
■
Alarm History Table
Refer to p. 51 Alarm History Table.
Note:
• Only WJ-SX650 or WJ-SX850 switch node
MON OSDAll On CAM
0123 Unit:01 00512