18
About external terminal
Important:
• Be sure to turn off the power of each device before connection.
Alarm output
Input specification:
Open collector out-
put (max. voltage: 16 V DC)
Off:
Internally pulled up
2 V to 4 V DC
On:
Output voltage 1 V DC or less (max.
drive current: 100 mA)
Functions:
Alarm output
* When an external device is connected, exercise care to avoid
exceeding the rating.
* Applicable wire: AWG #22 - #28 Single core, twisted
Before connection, remove 9 mm to 10 mm of the wire sheath and
twist the wire enough to prevent the short circuit.
* Check whether the stripped part of the wire is not exposed from
the external terminal and is securely connected.
POWER
ALARM OUT
GND
VIDEO OUT
220 - 240V ~ 50Hz
WV-CP500L
9 mm - 10 mm
ALARM OUT
GND
The external terminal is the same between
WV-CP500L and WV-CP504L.
Stripped
POWER
ALARM OUT
GND
VIDEO OUT
220 - 240V ~ 50Hz
WV-CP500L
9 mm - 10 mm
ALARM OUT
GND
The external terminal is the same between
WV-CP500L and WV-CP504L.
Stripped