background image

Ceiling Mount Bracket

Operating Instructions

WV-Q152C

Model Nos.

WV-Q152S

Before attempting to connect or operate this product,

please read these instructions carefully and save this manual for future use.

No model number suffix is shown in this manual.

NM0806-1096       3TR004562BAA       Printed in Japan

Preface

This bracket is exclusively designed to mount the network camera, DG-NS202, on a wall.
The network camera shall be mounted on this bracket after mounting this bracket on a ceiling.

• WV-Q152C: Clear dome cover
• WV-Q152S: Smoked dome cover (approx. 50 % of transmittance)

Precautions

• Refer installation work to the dealer.

Installation work requires technique and experiences. Failure to observe this may cause fire,
electric shock, injury, or damage to the product. Be sure to consult the dealer.

• Use only the specified camera.

Failure to observe this may cause a fall of an inappropriate camera resulting in injury or acci-
dents. Mount WV-NS202 on this bracket exclusively.

• Avoid installing this bracket in the locations where salt damage occurs or corrosive gas is

produced.

Otherwise, the mounting portions will deteriorate and accidents such as a fall of the camera may
occur.

• The screws and fixation mechanisms shall be tightened securely.

Failure to observe this may cause a fall of the camera resulting in injury.

• Select an installation area that can support the total weight.

If a selected area is too weak to support the total weight, a fall of the product may occur resulting
in injury. Installation work shall be started after sufficient reinforcement.

• Periodic inspections shall be conducted.

Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult the
dealer for the inspections.

• The measures of protection against a fall of the camera shall be taken.

Failure to observe this may cause injury. Be sure to install the safety wire.

• Do not rub the edges of metal parts with your hand.

Failure to observe this may cause injury.

• Make sure that the installation area is strong enough to hold the total weight of the camera

assembly (approx. 1.2 k

{2.6 lbs.}) before installation.

• The pull-out strength of the installation area shall be 196 N {20 k

g

f} or more per 1 screw. If a ceil-

ing board such as plaster board is too weak to support the total weight, the area shall be suffi-
ciently reinforced or the optional direct ceiling mount bracket for the camera, WV-Q105, shall be
used.

Procure 4 screws (M4 or M6) securing the camera mounting bracket (supplied with the camera)
according to the material of the installation area.  In this case, wood screws and nails should not
be used.
For mounting a camera on a concrete wall, use an anchor bolt (for M6) or an AY plug bolt (M4 or
M6) manufactured by Matsushita Electric Works, Ltd. for securing.
(Recommended tightening torque M4: 1.6 N·m {16 k

g

f·cm}, M6: 5.0 N·m {51 k

g

f·cm})

• Avoid installing in the following locations.

• Locations where it may get wet from rain or water splash (not only outdoor)
• Locations where a chemical agent is used such as a swimming pool
• Locations subject to steam and oil smoke such as a kitchen
• Locations where radiation or x-ray emissions are produced
• Locations where it may be damaged by briny air such as seashores
• Locations where the temperature is not within –10 °C - +50 °C {14 °F- 122 °F}.
• Locations subject to vibrations (This product is not designed for on-vehicle use.)
• Locations where the temperature may rapidly change such as the peripheral areas of the air

outlets of air conditioners or doors facing outside. (In case of installing the camera in such
locations, the dome cover may become foggy or condensation may be caused on the cover.)

• The screws and bolts must be tightened with an appropriate tightening torque according to the

material and strength of the installation area. After tightening the screws or bolts, perform visual
check to ensure tightening is enough and there is no backlash.

• The protection sheet attached to the dome cover shall be peeled off after installation.

Major Operating Controls and Their Functions

* If a microphone is used, mount the microphone on the rubber-made microphone stand. Unless the

microphone is used, cut the rubber with a nipper or conduct another treatment.

<For using the direct ceiling mount bracket for the camera, WV-Q105>

LOCK

OPEN

Notch for network cable, monitor
output cable, etc.

Dome cover

Ceiling mount bracket

Hole for microphone cable

Microphone stand*

Installations

Be sure to read "Precautions" before installation.
The Installation Guide of the network camera, WV-
NS202, shall be read as well.

1. Install the inner shell.

Slide the covers located on the both lateral
sides of the camera and put the inner shell on
the camera until the hooks inside the inner shell
are held in the holes of the camera (until a click
is heard).

Important:

Put the inner shell down on the cam-

era until the outside cover of the camera
cannot be seen from the opening (from
which the camera lens is visible) of the inner
shell. If this integration is not successfully
performed, the inner shell may be removed
or the hidden part at the top of the screen
may become larger in the WIDE mode.

Cover

Hook

Put on until a click is heard

Inner shells

How to remove the inner shell

Press the inner shell from the front and rear
sides inward (at the same vertical position
as the hooks) to bend the shell and remove
the shell from the camera.

Press from the front and rear
sides inward to bend

(To be continued reverse page)

Anchor bolt
(Procured locally)

Safety wire angle
(WV-Q105 supplied)

Safety wire
(WV-Q105 supplied)

Ceiling board such as plaster board

Ceiling mount bracket

Inner shell

Dome cover

Mounting screws (4 pcs.)
WV-Q105 supplied)

WV-Q105 (option)

Reviews: