Rear view
MONITOR OUT
AUDIO OUT
MIC/LINE IN
EXT I/O
4 3 2 1
12V IN
POWER
INITIAL
SET
ACT
LINK
10BASE-T/
100BASE-TX
Safety wire holder
Monitor out connector
for adjustment
Audio output connector
Microphone/line input connector
External I/O terminals
12 V DC power supply terminal
INITIAL SET button
Cable guide
Network connector
Link indicator
(lighting at linking)
Access indicator
(blinking at accessing)
About the [INITIAL SET] button
After turning off the power of the camera, turn on the power of the camera while holding down this button, and wait for
around 5 seconds or more without releasing this button. Wait around 3 minute after releasing the button. The camera will
start up and the settings including the network settings will be initialized. Before initializing the settings, it is recommended
to write down the settings in advance. The initialization will be complete when the live indicator stops blinking orange and
lights off. Note that the preset position settings and the CRT key (SSL encryption key) used for the HTTPS protocol will not
be initialized.
Important:
• Do not turn off the power of the camera during the process of initialization. Otherwise, it may fail to initialize and may
cause malfunction.
Bottom view
Screw hole for a tripod
(1/4-20 UNC for tripod)
Important:
• Do not use this hole to mount on the ceiling since the fall prevention measure is unavailable.
14