[SSL]
Select “On” if you want to use SSL encryption when sending E-mail notifications for alarm occurrences or the
“Diag.” function. When you select “On”, the authentication method will be set to “SMTP”. Set the user name
and the password used for authentication.
•
Default:
Off
Note
•
Some SMTP servers may not support SSL.
•
SSL supports SMTP over SSL, but STARTTLS is not supported.
•
When “On” is selected, the SMTP port number may need to be set to 465. Ask your Internet service
provider for the appropriate settings.
[Address 1] - [Address 4]
Enter the destination E-mail address. Up to 4 destination E-mail addresses can be registered.
•
[Alarm] checkbox:
When the checkbox is selected, the E-mail notification will be performed upon an alarm
occurrence.
•
[Diag.] checkbox:
When the checkbox is selected, the E-mail notification will be provided in the following
cases.
–
When notification of the remaining capacity of the SD memory card has been provided
–
When the SD memory card has become full
–
When the SD memory card cannot be recognized
•
[Destination E-mail address]:
Enter the destination E-mail address.
–
Available number of characters:
3 - 128 characters
–
Available characters:
Alphanumeric characters, the at sign (@), the period (.), the underscore (_),
and the hyphen (-).
To delete the registered address, click the [Delete] button respective to the desired address.
Terminal 1:
SFx311
SFx310
SPN311
SPN310
SPW311L
SPN531
SPW531L
E-mail notification will be
performed upon a terminal 1 alarm.
Terminal 2:
SFx311
SFx310
SPN311
SPN310
SPW311L
SPN531
SPW531L
E-mail notification will be
performed upon a terminal 2 alarm.
Terminal 3:
SFx311
SFx310
SPN311
SPN310
SPW311L
SPN531
SPW531L
E-mail notification will be
performed upon a terminal 3 alarm.
VMD:
E-mail notification will be performed upon a VMD occurrence.
Audio detection:
SFx311
SPN311
SPW311L
SPN531
SPW531L
SFN310
SPN310
E-mail notification will
be performed upon an audio detection.
Command alarm:
E-mail notification will be performed upon a command alarm entry.
Diag.:
–
With the SD memory card remaining capacity notification (Destination of notification “Diag.” column)
–
With the SD memory card full notification (Destination of notification “Diag.” column)
–
With the SD memory card recognition error notification (Destination of notification “Diag.” column)
Default:
None (blank)
Note
•
Entering alternative text into the E-mail body automatically adds the event or time when an alarm
occurs.
Alternative text alarm event: %p%, occurrence time: %t%
(Examples of use)
After setting the following characters in the E-mail body, there is a Terminal 1 alarm occurrence at the
time 19:13:24
E-mail body settings: %p% alarm occurred at %t%.
Sent E-mail body: “A “Terminal 1” alarm occurred at 19:13:24.”