13 Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence or
alarm images, the VMD area settings, audio detection settings, and the alarm occurrence notification can be
configured on this page.
The “Alarm” page has the [Alarm] tab, the [VMD area] tab, the [Audio detection] tab, and the [Notification] tab.
13.1 Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
The settings relating to the alarm can be configured in this section. Refer to page 120 and page 118 for further
information about the settings relating to the alarm images and the alarm output terminal.
Alarm
[Terminal 1]
SFx311
SFx310
SPN311
SPN310
SPW311L
SPN531
SPW531L
Determine how to use terminal 1.
•
Off:
Not used.
•
Alarm input:
Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close” and
“Open” is displayed.
–
Close:
An alarm is detected when the terminal status is changed to “Close”.
–
Open:
An alarm is detected when the terminal status is changed to “Open”.
•
Black & white input
SFx311
SPN311
SPW311L
SPN531
SPW531L
:
Receives the black & white
switchover input. (When the input is set to On, the black & white mode is activated.)
•
Auto time adjustment:
Receives the time adjustment input. When the signal is received and if the clock
is within 29 minutes ± the hour, the time will be adjusted to 00 minutes 00 seconds. When the time setting
is moved back by less than 5 seconds, the time is not changed. When “Auto time adjustment” is selected,
a pull-down menu for “Close” and “Open” is displayed.
–
Close:
The time is adjusted when the terminal status is changed to “Close”.
–
Open:
The time is adjusted when the terminal status is changed to “Open”.
•
Default:
Off
[Terminal 2]
SFx311
SFx310
SPN311
SPN310
SPW311L
SPN531
SPW531L
Determine how to use terminal 2.
116
Operating Instructions
13 Configure the alarm settings [Alarm]