[Delete] button
Deletes the VIQS area. Click the button to delete the VIQS area.
[Level]
Configure the difference level in the image quality between specified areas and non-specified areas. The
greater the difference level, the more the image quality of the non-specified area is reduced. This makes it
possible to moderate the image data size.
0 Min./ 1/ 2/ 3/ 4/ 5 Normal/ 6/ 7/ 8/ 9 Max.
•
Default:
5 Normal
Stream
[Stream(1)]
Select “On” or “Off” to determine whether or not to activate the VIQS function for the transmitted (Stream(1))
images.
The VIQS (Stream(1)) images can be confirmed with the [Confirm] button.
•
Default:
Off
[Stream(2)]
Select “On” or “Off” to determine whether or not to activate the VIQS function for the transmitted (Stream(2))
images.
The VIQS (Stream(2)) images can be confirmed with the [Confirm] button.
•
Default:
Off
[Stream(3)]
Select “On” or “Off” to determine whether or not to activate the VIQS function for the transmitted (Stream(3))
images.
The VIQS (Stream(3)) images can be confirmed with the [Confirm] button.
•
Default:
Off
IMPORTANT
•
After the VIQS setting is set to “On”, the VIQS area may move out of alignment when the “Image capture
mode” setting on the [Image] tab of the “Image” page is changed. Make sure to check the VIQS setting
after changing the “Image capture mode” setting.
Note
•
Refer to page 91 for setting procedure of the VIQS area.
•
When “Off” is selected for “Stream transmission” of the applicable stream, the stream selection cannot
be changed.
90
Operating Instructions
2 Settings