background image

7

q

Alarm Indicator (ALARM)

Blinks to indicate that an alarm condition exists.
It changes to steady light when the alarm is reset auto-
matically.
To turn the indicator off, press the ACK RESET button.

w

Busy Indicator (BUSY)

Lights up when you attempt to control a monitor or a
camera that is already used by a higher priority opera-
tor, or when the higher priority operator selects the
monitor or camera you are currently operating.
Operations from the System Controller are disabled
until this indicator goes off.

e

Function Buttons (F1/F2/F3/F4)

Select functions displayed on the LCD (Liquid Crystal
Display) display.

r

LCD (Liquid Crystal Display) Display

Displays function menus, numeric input, and system
status.

t

Direction Buttons (

A

B

D

C

)

Select a function menu for display on the LCD display.

y

Zoom Wheel Controller

This control is used for zooming cameras equipped
with the specified lens. Moving the control to the right
will zoom in the image. Moving the control to the left will
zoom out the image.

u

Joystick Controller (UP/DOWN/LEFT/RIGHT)

The joystick is used to manually operate the Pan/Tilt
Head, or move the cursor in the Matrix Switcher’s Setup
Menu on the active monitor screen.

i

Top Button

Pressing this button will automatically set the lens focus
of a specified camera.

o

Iris Control Buttons (IRIS CLOSE, OPEN)

Close or open the lens iris of cameras equipped with
the specified lens.
When these buttons are pressed at the sometime for 3
seconds or more, the lens iris is reset to the factory
default setting.

!0

Focus Control (FOCUS NEAR/FAR)

Adjust the lens focus of cameras equipped with the
specified lens.

!1

Zoom Control (ZOOM TELE/WIDE)

This control is used for zooming cameras equipped
with the specified lens.

!2

Preset Button (PRESET)
Auto Focus Button (AF)
PRESET:

This button, in combination with the Numeric

keys, is used to move the selected camera to a pre-
set position in a system equipped with the specified
cameras.

AF:

Pressing this button will automatically set the lens

focus of a specified camera.

!3

Camera (Set) Key [CAM (SET)]
CAM:

Used for camera selection. To select a camera,

enter the desired camera number with the Numeric
keys, and then press the CAM key.

SET:

This key, in combination with the Numeric keys, is

used to enter numeric input, such as operator ID
and password.
It is also used to execute the currently highlighted
selection and to enter a submenu in the Setup
Menu of the Matrix Switcher.

!4

Numeric Keys (0 to 9)

These keys are used for numeric input into the system,
such as the camera and monitor number, sequence
number, preset position, etc.

!5

Monitor (Escape) Key [MON (ESC)]
MON:

This key is used to select a monitor.

To select a monitor, press the corresponding
Numeric keys, followed by the MON key.

ESC:

This key is used to escape from the currently

highlighted selection on the Setup Menu of the
Matrix Switcher.

Pressing this key, while the Alternate (ALT) indicator is
on, will display the video that is connected to the
Monitor Input (MONITOR IN) Connector on the WV-
PB5504A Video Output Board.

!6

Stop/Slow Button (STOP/SLOW)
STOP:

Pauses a sequence that is being run on the

active monitor.

SLOW:

For fine pan/tilt control, move the joystick while

holding down the SLOW button.

!7

Increment Button (INC +1CAM)

When a sequence running in forward direction has
been paused with the STOP button, pressing this button
will move the sequence one frame to the next step (in
forward run direction). If the sequence was running in
reverse direction, the button will move the sequence
one frame to the next step (in reverse run direction).
This button is also used to select a camera. Pressing
this button will replace the currently selected camera
with the next higher camera number, if the active moni-
tor is in Spot mode.

Summary of Contents for WVCU550CJ - SYSTEM CONTROLLER

Page 1: ...ual for future use Model No WV CU550CJ System Controller Operating Instructions ALARM ACK RESET AUX DEC 1CAM INC 1CAM STOP SLOW ESC SET MON CAM WIDE FAR AF ZOOM TELE FOCUS NEAR RESET IRIS 1 2 3 4 5 6 7 8 0 9 CLOSE OPEN 1 2 BACK SEQ FORWARD SEQ ALT BUSY F1 F2 F3 F4 System Controller WV CU CJ 550 ENGLISH FRANÇAIS ...

Page 2: ...ications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution To assure continued compliance example use only shielded interface cables when connecting to com puter or peripheral devices Any changes or modifications not expressly approved by the party responsible ...

Page 3: ... outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparat...

Page 4: ... to any one of 16 monitors Remote control of up to 128 cameras and auxiliary equipment by using optional receivers and accessories including 1 Remote control of Pan Tilt Head and Camera Housing 2 Remote control of Motorized Zoom Lenses Focus Zoom and Iris 3 Remote control of camera settings including Electronic Sensitivity Enhancement Electronic Shutter Electronic Zoom and more Selection of variou...

Page 5: ...r try to operate it in wet areas Take immediate action if the appliance becomes wet Turn the power off and refer servicing to qualified ser vice personnel Moisture may damage the appliance and also cause electric shock Do not use strong or abrasive detergents when cleaning the appliance body Use a dry cloth to clean the appliance when it is dirty When the dirt is hard to remove use a mild detergen...

Page 6: ...AF ZOOM TELE ESC SLOW ALT BACK SEQ ACK RESET FORWARD SEQ DEC 1CAM AUX INC 1CAM STOP 2 1 F3 F4 1 2 3 4 5 6 7 8 9 MON 0 CAM CLOSE OPEN IRIS PRESET FAR FOCUS NEAR q w r t y i 0 3 4 5 6 7 8 9 2 1 2 o e u 3 1 0 CONTROLLER CONTROLLER UNIT No 1 8 MODE DATA TERM ON ON OUT OFF OFF IN 54 3 2 1 0 9 8 7 6 4 5 6 7 8 9 Rear View ...

Page 7: ...ton AF PRESET This button in combination with the Numeric keys is used to move the selected camera to a pre set position in a system equipped with the specified cameras AF Pressing this button will automatically set the lens focus of a specified camera 3 Camera Set Key CAM SET CAM Used for camera selection To select a camera enter the desired camera number with the Numeric keys and then press the ...

Page 8: ...d from the step that was previously paused by pressing the Stop button 3 Alarm Acknowledge and Reset Button ACK RESET This button cancels an activated alarm To cancel an alarm first select the alarmed monitor s then press the ACK RESET button once for alarm acknowledgment the indicator on the button blinks rapidly and finally press it again for alarm reset the indicator goes off After an alarm ack...

Page 9: ...l on the controller shown below Refer to the Operating Instructions of WJ FS616 Series for further details Note Locate the System Controller in a level place INSTALLATION ALARM ACK RESET AUX DEC 1CAM INC 1CAM STOP SLOW ESC SET MON CAM WIDE FAR AF ZOOM TELE FOCUS NEAR RESET IRIS 1 2 3 4 5 6 7 8 0 9 CLOSE OPEN 1 2 BACK SEQ FORWARD SEQ ALT BUSY F1 F2 F3 F4 System Controller WV CU CJ 550 ...

Page 10: ...y pressing the STOP SLOW button is enabled only when FST mode is selected The above function is available in a system that includes the following equipment WJ SX550 Series Matrix Switcher CPU Ver 6 00 or later Control Ver 6 00 or later WV PB5548 Data Board Ver 6 00 or later Version Information WJ SX550 Series Matrix Switcher The onscreen display indicates the version in Cold Start or Normal Start ...

Page 11: ...oster On Off Camera On Off Pan Tilt Manual Pan Right Left Manual Tilt Up Down Auto Pan On Off Random Pan On Off Preset Home Auxiliary Switch AUX 1 and 2 On Off Unit Number 1 to 8 Ambient Operating Temperature 10 C to 50 C 14 F to 122 F Ambient Operating Humidity Less than 90 Dimensions 370 mm W x 129 mm H x 221 mm D 14 9 16 W x 5 1 8 H x 8 11 16 D Weight 2 2 kg 4 8 lbs Weight and dimensions indica...

Page 12: ... Km 9 5 San Gabriel Industrial Park Carolina Puerto Rico 00985 809 750 4300 Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Southern 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Mid...

Reviews: