24
※
●
●
1
2
·
·
●
3
●
●
●
→
●
●
●
※
1
2
Notice
Anti-fungus assembly
<About once a month>
Do not scrub it with a brush, nor disassemble it.
Wash it with water.
Check whether the housing of the anti-fungus assembly is dirty.
If dirty, wipe it clean with a soft cloth.
Anti-fungus
agent
Housing
The anti-fungus agent has its own special smell, harmless to humans.
The anti-fungus agent will be small along with the use. This
is not a problem with the anti-fungus performance.
The anti-fungus assembly may have powder sometimes.
This is normal and not a problem with use.
(For removal and installation methods of tray, please see page 23.)
(For removal and installation methods
of tray, please see page 23.)
Sterilization filter assembly
<About once a month>
Disassemble
Remove the filter plate and
sterilization filter from the
filter frame.
Filter frame
Filter plate
sterilization filter
Do not
reverse it
Open
Wash
Wash the filter frame and filter plate with water
Do not dry it with a drier. (Doing this may cause shrinkage)
Do not scrub it with a brush or wash it with a washing
machine.
Press and wash sterilization filter with clean/
warm water.
Do not leave a gap between the sterilization filter and the filter plate as
well as the filter frame, nor press the round parts of both ends.
(Otherwise, performance degradation may be caused.)
Install the filter plate onto the filter frame.
Insert the sterilization filter into the filter frame.
Install
After replacement, fill in the replacement date on the back label of the product.
Please dispose of the used sterilization filter as non-combustible garbage. However, do not discard
the filter frame and filter plate.
As the degree of dirtiness varies with the water quality and operating environment, replacement may
be required even within 5 years if there is still an unpleasant odor or the water in the tank is reduced
at a slower speed upon maintenance.
(Optional accessories: Page 26)
The product runs 12 hours a day.
Conditions
Replacement cycle
Reference replacement cycle of the sterilization filter
About once every 5 years