EN 14
1.
Set the rotary switch to the position
2.
Attach the pin-plug of the black test lead to the COM-jack and the
pin-plug of the red test lead to the V, Ω, Hz %-jack.
3.
Connect the black test prod to the negative pole and the red test prod
to the positive pole of the circuit to be tested.
4.
If the resistance is less than about 50 Ω, you hear an audible signal. If
the circuit is open, the display shows “OL”.
Diode testing
1.
Set the rotary switch to the position
2.
Touch the diode to be tested with the probes. The forward voltage shows
400 to 700mV. The counter voltage shows „OL”. Defective devices show a
value about 0 mV or „OL” in both polarities.
Frequency measurement and Duty cycle
1.
Set the rotary switch to the position
Hz %
2.
Select with the FUNCTION button
Hz
or
%
3.
Attach the pin-plug of the black test lead to the COM-jack and the pin-plug
of the red test lead to the V, Ω, Hz %-jack.
4.
Connect the black test prod to the negative pole and the red test prod to
the positive pole of the circuit to be tested.
5.
Once the reading stabilizes, read the value. If the polarity is twisted a
"Minus sign" is displayed. Use the HOLD function if the reading is difficult
to read.
Capacity measurement
1.
Set the rotary switch to the position
2.
Attach the pin-plug of the black test lead to the COM-jack and the pin-plug
of the red test lead to the V, Ω, Hz %-jack.
3.
For capacitors with known polarity connect the red test lead with the
anode and the black test lead with the cathode. Once the reading
stabilizes, read the value. Use the HOLD function if the reading is difficult
to read.
Relative mode (REL)
The relative measurement feature allows you to make measurements relative
to a stored reference value. A reference voltage (current, etc.) can be stored
Summary of Contents for PAN 185
Page 1: ...MANUAL PAN 185 ...
Page 3: ...Bedienungsanleitung PAN 185 Digitalmultimeter ...
Page 11: ...DE 9 Nebenanzeige Kleine Ziffern Luftfeuchte RH in Umgebungstemperatur C oder F ...
Page 22: ...Manual PAN 185 Digitalmultimeter ...
Page 40: ...Manuel d instructions PAN 185 Multimètre numérique ...
Page 59: ...Istruzioni per l uso PAN 185 Multimetro digitale ...
Page 67: ...IT 9 Display secondario Numeri piccoli Umidità dell aria RH en Temperatura ambiente C o F ...
Page 78: ...Gebruiksaanwijzing PAN 185 Digitale multimeter ...
Page 97: ...Bruksanvisning PAN 185 Digital multimeter ...
Page 115: ...Návod na používanie PAN 185 Digitálny multimeter ...
Page 134: ...Használati útmutató PAN 185 Digitális multiméter ...
Page 153: ...Navodila za uporabo PAN 185 Večnamenski digitalni merilnik ...
Page 171: ...Upute za uporabu PAN 185 Digitalni multimetar ...
Page 189: ...Instrucţiuni de folosire PAN 185 Multimetru digital ...