19
Optimized
ventilation
> 20mm
INSTALLATION INSTRUCTIONS
The installation comes under the exclusive responsibility of specialists.
The installer is held to respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
•
The cut out sizes are:
•
The plate is equipped with two fans located at the bottom.
Please observe the distances
•
for the circulation of the ventilation air.
Ensure that there is a distance of 50mm
•
between the hob and the wall or sides.
The ventilation distance between the plate base and the upper section of a ventilated oven
or drawer, must beat least 20mm. The separation distance for non forced ventilation ovens
must be greater in accordance with the oven manufacturer’s recommendations.
Cut size
Glass size
Model
Thickness
Depth
Width
Depth
Width
PI3100
4
520
590
490
560
PI3400
4
370
810
340
780
Stick the gasket (2) two millimeters from
the external edge of the glass, after
removing the protection sheet (3).
¡ATTENTION!
Inproper installation
and dailure to
observe the
ventilations may lead
to malfunction of
breakdown of the
device that is not
covered by the
manufacturer’s
warranty