23
22
USER MANUAL
PANDORA DXL 1100L SERVICE-SECURITY
R E M O T E C O N T R O L
VEHICLE STATUS CONTROL
To receive information about engine, exterior temperature, battery voltage and fuel
level, select
«System controls»
menu and shortly press
button.
To exit menu, press and hold button for 1 second.
Note: Engine temperature indicating is available only if temperature sensor is connected.
The sensor availability depends on the system set
remote start
settings
system
controls
CHECK
channel
management
1 2 3
4 5
6
7
8 9
arming
12:43
disarming
12:44
system
controls
CHECK
arming
12:43
disarming
12:44
system
controls
CHECK
EVENT HISTORY
To view event history in the system’s memory, select
«System controls»
menu,
then shortly press
button. Navigate several last events using
(forward)
and
(back). Events are displayed by showing time of the event and flashing
corresponding trigger zone indicators.
WIRING DESCRIPTION
Х1 SOCKET (MAIN)
Wire «1» (Black)
— It should be grounded (attached to the motorcycle body). This
wire must be connected first during the installation.
Wire «2» (Orange) (CH7+)
— Factory preset is «Control turn indicators». It
connects to (+) control wire of the right turn signals (maximum load current is 6A).
This output is multipurpose, it can operate in accordance with selected logic.
Wire «3» (White) («Tachometer input »)
— analog input of the tachometer signal,
it connects to the tachometer wire or to the signal wire of nozzle, which provide table
pulses of any polarity corresponding to the RPM.
Wire «4» (Orange) (CH6+)
— Factory preset is «Control turn indicators». It
connects to (+) control wire of the left turn signals (maximum load current is 6A). This
output is multipurpose, it can operate in accordance with selected logic.
Wire «5» (Gray) (INP4-/CH1-)
— Factory preset is «Clutch». It connects to
appropriate wire that becomes grounded when clutch handle is pressing. This channel
is universal and can operate as an input or output in accordance with selected logic.
Wire «6» (Green) (CH4-)
— Factory preset is «N.O. blocking». The channel is used to control
blocking relay with normally open logic (it becomes grounded when switching on the ignition
and security system is not armed). A negative output of additional channel with maximum load
current 200mA. This channel is universal and can operate in accordance with selected logic.
Wire «7» (Purple) (CH5+)
— Factory setting is «Siren». It connects to siren control
wire (+) (maximum load current is 2A). This output is multipurpose, it can operate in
accordance with selected logic.
W I R I N G D E S C R I P T I O N • W I R I N G D I A G R A M