27
26
USER MANUAL
PANDORA DXL 1100L SERVICE-SECURITY
R E M O T E C O N T R O L
AUTOMATIC ENGINE START
The system allows setting up modes of automatic engine start and stop. Synchronized
real-time clock on the remote control and base unit and other autonomous system
settings allow many engine start options without needing to have the remote control
in command radio range. Automatic start and engine work conditions programming
is done using LCD remote. Shortly press
button to enter
«Remote start
settings»
menu. Shortly press button to switch between menu sublevels. Sublevel
values are changed using
and
buttons.
When changing settings are done, the values should be saved. To do this, proceed
to «Send settings» sublevel by pressing of button and press
button to save
new settings. Changes will be sent to the base unit, it will be confirmed with double
sound signal of the remote control.
To exit menu, press and hold button for 1 second.
Note: If you have not saved new settings, remote and automatic engine start settings will
remain the same as before.
Note: Engine start via temperature is available only if temperature sensor is connected. The
sensor availability depends on the system set.
Wire «8» (Red) (INP+) («Power supply» +12V)
— It should be connected to
reliable conductor with constant voltage of 12V.
Wire «9» (Yellow) (INP+)
— Factory setting is «Ignition». This wire connects to
ignition switch or to appropriate wire where +12V voltage appears when ignition is
enabled and doesn’t disappear until the moment ignition is disabled. This input is
multipurpose, it can operate in accordance with selected logic.
Wire «10» (Brown-yellow) (INP1-)
— Factory preset is «Trunk». It connects to
appropriate wire that becomes grounded when a pannier opens or to a seat opening
trigger. This input is multipurpose, it can operate in accordance with selected logic.
Wire «11» (Brown) (INP2-)
— Factory preset is «Neutral». This wire should be
connected to the wire which becomes grounded when the gear lever is in the «neutral»
position. The ‘Neutral’ signal is one of the controlled zones for remote start procedure.
This input is multipurpose, it can operate in accordance with selected logic.
Wire «12» (Blue-white) (INP3+)
— Factory preset is «Brake». It connects to a
brake trigger that r12V when a brake is pressed. The ‘Brake’ signal is one of the
controlled zones for remote start procedure. This input is multipurpose, it can operate
in accordance with selected logic.
Wire «13» (Pink) (CH3-/INP6-)
— Factory preset is «Starter». This output is used to
control starter relay. A negative output of additional channel with maximum load current
200mA. This channel is universal and can operate in accordance with selected logic.
Wire «14» (Blue) (CH2-/INP5-)
—
Factory preset is «Ignition». The output is used
to control ignition relay. It is required for implementing remote start function, ignition
maintenance and for in series (incut) connection of the ignition. A negative output of
additional channel with maximum load current 200mA. This channel is universal and
can operate in accordance with selected logic.
W I R I N G D E S C R I P T I O N • W I R I N G D I A G R A M