background image

29

28

U S E R   M A N U A L

P A N D O R A   D X L   1 9 2 0 L / 1 9 3 0 L   C A R   S E R V I C E - S E C U R I T Y   S Y S T E M

confirm the resetting to the factory settings with a long red flash of LED indicator. After that the system 

will return to a programming mode.

Level 5 – Recording Bluetooth engine compartment module

To record a Bluetooth engine compartment module, enter programming mode and press 

VALET 

button 5 times. The

 LED

 indicator will light green and the system will enter the recording of an engine 

compartment module mode. Connect the module in accordance with installation manual. The system 

will confirm the registration with a short sound signal.

Saving changes:

To finish the recording of the engine compartment module, 

VALET

 button should be pressed once 

again, the series of red and green flashes of the status 

LED

 will confirm the saving, switch on the ignition 

to automatically save the settings and exit programming mode.

Levels 6, 7 – Recording Bluetooth radio relays 

Radio relays recording is performed one by one starting from the 6 level: radio relay №1 

is recorded on the 6 level; radio relay №2 is recorded on the 7 level. The radio relay can be 

overwritten only on the level of its initial registration.

To record Bluetooth radio relays №1, №2, enter programming mode and press

 VALET

 button 6 times 

for radio relay №1 or 7 times for radio relay №2.

 LED

 indicator will light green and the system will enter 

the recording of a radio relay mode. Connect a relay in accordance with installation manual. The system 

will confirm recording with a short sound signal.

Saving changes:

To finish the recording of the Bluetooth radio relay, 

VALET

 button should be pressed once again, the 

series of red and green flashes of the status 

LED

 indicator will confirm the saving, switch on the ignition 

to automatically save the settings and exit the programming mode.

Level 10 – Configuring system settings via the wireless interface

This function is under construction.

Level 11 – Programming and configuring “Immobilizer code“

To program the “Immobilizer code“, enter the programming mode and press 

VALET

 button 11 

times. The level is divided into 3 sublevels (Sublevel 11.1 – Selecting buttons; sublevel 11.2 entering 

PIN-code; sublevel 11.3 – confirmation of the PIN-code input).

The system will automatically enter the sublevel 11.1 (Selecting buttons) after entering the level 11. 

The system can determine buttons via analog “Code immobilizer” input or via digital protocol of a car. 

It is necessary to configure an analog input (INP) as “Code immobilizer“ in the settings of the base unit 

inputs when implementing the “Code immobilizer” via an analog input. It may be necessary to switch on 

the ignition after entering the level 11 of programming (if the car bus is active only when the ignition is 

switched on) when implementing the “Code immobilizer” via digital car bus protocol.

After selecting active buttons enter the sublevel 11.2 (Entering PIN-code) by pressing 

VALET

 button 

once. Program PIN-code using selected buttons at this sublevel; press VALET button once and enter PIN-

code again. To confirm PIN-code re-entering and save all the settings press 

VALET

 button once again.

Sublevel 11.1 – Selecting buttons:

This sublevel is used to select active buttons via digital protocol of a car or via “Code Immobilizer“ 

analog input. To determine the activity of the analog “Code Immobilizer“ input, apply potential to the 

corresponding input (INP) of the base unit, 

LED

 indicator will be flashing orange. 

If you determine buttons via digital protocol select one or more buttons (up to four) for entering 

the secret code of the immobilizer. To do this press the selected button, 

LED

 indicator will confirm input 

with orange flashes. If there are no orange flashes when any button is pressed, then this button is not 

recognized by the system, select a different button. Repeat the procedure to select the second, third, 

fourth button and enter the next sublevel. To enter the next sublevel press 

VALET

 button once.

Sublevel 11.2 - Entering PIN-code:

Program immobilizer deactivation PIN-code using selected button or buttons. Enter the first digit by 

pressing the previously selected button (pauses between presses should not exceed 1 second). The base 

unit will confirm entering with red flash of 

LED

 indicator. Enter the second (third, fourth) digit by pressing the 

previously selected button. The base unit will confirm entering of each digit with red flash of 

LED

 indicator.

 Input the required number of digits (up to 4) and then press 

VALET

 button. The system will confirm 

receiving of the secret validator code with long red flash of 

LED

 indicator and will wait for confirmation 

of PIN-code.

Sublevel 11.3 - Confirmation of the PIN-code input:

Enter PIN-code again similarly to the procedure (level 11.2 – Entering PIN-code) and press 

VALET

 

button. The system will confirm correct PIN-code with red and green flashes of

 LED

 indicator and will 

memorize PIN-code, and then the system will proceed to programming mode awaiting level input. 

Incorrect confirmation is indicated with long red flash of

 LED

 indicator, after that the system will return 

to programming mode.

Level 15 – Disabling/enabling immobilizer tag

To disabling/enabling of immobilizer tag, enter programming menu and press 

VALET

 button 15 

times. 

LED

 indicator will light green (green light indicates enabled tag) and the system will wait for the 

“Secret PIN-code” entering. Red light of 

LED

 indicates disabled immobilizer tag.

Disabling radio tag:

LED 

indicator will light green after entering the programming level. The system will wait for entering 

the “Secret PIN-code“. Enter the “Secret PIN-code“ that is written on the owner’s plastic card. The system 

will confirm disabling of the radio tag with two sound signals of the siren and a long red 

LED 

flash. After 

Summary of Contents for DXL 1930L

Page 1: ... and support on the territory of Russain Federation and nearest states We are happy to provide any support we can feel free to use our online support This device has limited external factors resistance It should not be subjected to water beyond occasional splatter or operated in temperatures outside 40 to 80 C range IMPORTANT Note that this manual describes remote and manual functions for the most...

Page 2: ...g disarming in Hands Free mode 7 Arming disarming in Slave mode 7 Immobilizer mode 8 Anti Hi jack mode 8 Code immobilizer using original car controls 9 Replacing immobilizer tag battery 9 Control over the system in case of emergency 9 Emergency disarming using VALET button 10 Enabling Disabling immobilizer radio tag 11 Control over the system via a phone 12 DTMF commands 12 Changing core settings ...

Page 3: ...28 bit encryption key Built in LED indicator Built in button to control over security modes Built in integral accelerometer Car security zones Pandora DXL 1920L 1930L service security system guards following independent zones car doors perimeter front hood triggers trunk triggers ignition trigger brake pedal pressing triggering of the built in shock sensor warning level Availability of this functi...

Page 4: ...ly To disarm the system move toward the car with remote tag Enabling disabling this function can be performed with a phone see Control over system via a phone section Arming disarming in Slave mode In this mode it is possible to monitor the status of original security system of the car via CAN bus or by analog inputs When arming and disarming original security system Pandora will be armed and disa...

Page 5: ...eled and the system will return to the normal operation If the engine is blocked via analog relay engine operation will be stopped after warning signals are over until a registered tag appears in the radio zone or on registering movement depending on the settings Code immobilizer using original car controls Codeimmobilizer validator isafunctionthatallowsdisarming disablingblockingandcontrollingtim...

Page 6: ... incorrect it will be indicated with a red LED indicator flash and the system will stay in a previous state New input can be attempted after 5 seconds If the system was disarmed and the ignition was switched off it will enter programming mode after correct input of the PIN code For emergency arming when the ignition is switched off press and hold VALET button for 3 seconds The system will be armed...

Page 7: ...d Voice help The system has voice help menu During voice call to the system dial 9 and listen to the information about system control commands To end session hang up the phone Repeat the last message To repeat any message press during a voice call to the system Arming disarming 1 Call the system number Wait for answer 2 Dial 1 to arm and 0 to disarm For silent arming dial 10 or 00 for silent disar...

Page 8: ...he phone Tow truck mode This mode is intended for car transportation with preservation of arming function Tow truck mode can be activated only when the system is armed it will be deactivated automatically when disarming 1 Call the system number If the system is in PANIC mode receive emergency call Wait for answer 2 Dial 15 to enable Tow truck mode the system will disable motion shock and tilt sens...

Page 9: ... Remote blocking 1 1 2 2 3 3 Set threshold voltage for sending text message 5 5 5 5 Settings of saving mode GSM connection Money saving mode of the GSM connection Voice calls in roaming service 1 1 2 2 3 3 8 8 Current time and date settings 9 9 NOTE Engine start via temperature is available only if temperature sensor is connected The sensor availability depends on the system set INSTALLATION AND C...

Page 10: ...n operate in accordance with selected logic Wire 11 Orange black CAN1 Low It connects to appropriate CAN Low wire of the car Wire 12 Yellow black CAN2 Low It connects to appropriate CAN2 Low wire of the car Wire 13 Blue Black CH3 Factory setting is Blocking N O This output is used to control blocking relay with a normally open logic it becomes grounded when switching on the ignition and security s...

Page 11: ... mA 200 mA 200 mA CH5 Output to beeper CH1 INP1 Doors triggers CH4 INP4 To turn signals to original wiring INP5 Brake pedal input INP3 Front hood Trunk triggers СH3 OUT NO Blocking INP2 To ignition lock Siren 3А Ground CH2 CAN1 CAN1 H CAN1 L CAN2 CAN2 H CAN2 L X6 X1 X1 X2 X6 X6 X5 X5 X5 X3 X4 X4 X4 Relay module wiring diagram is on the next page Blue 9 Brown White 10 Orange Black 11 Yellow Black 1...

Page 12: ...e socket are available in AlarmStudio Disconnect the system from power supply after changing the settings PROGRAMMING THE SYSTEM Entering programming menu To change the system settings or program the system using a computer or VALET button the system should be in programming mode Enter programming mode by entering Service PIN code factory preset is 1 1 1 1 PIN code should be entered using external...

Page 13: ...t been installed in the vehicle yet it will be powered via micro USB cable while programming To program using a computer you need a standard USB cable a computer with Windows XP Vista 7 8 10 and Pandora AlarmStudio application you can download it from pandorainfo com It is required to create an account in AlarmStudio to use Pandora CLONE for remote engine start you can register without a connectio...

Page 14: ...ALET button Press the button a number of times equals to the first digit Pauses between presses should not exceed 1 second every pressing will confirm with orange LED indicator flash Pause for more than 1 second and red LED indicator confirms the input of the first digit Then you can enter the next digit Enter the other numbers in the same manner The input of the fourth number will be confirmed by...

Page 15: ...witched on when implementing the Code immobilizer via digital car bus protocol After selecting active buttons enter the sublevel 11 2 Entering PIN code by pressing VALET button once Program PIN code using selected buttons at this sublevel pressVALET button once and enter PIN code again To confirm PIN code re entering and save all the settings press VALET button once again Sublevel 11 1 Selecting b...

Page 16: ... allowed without deleting procedure When you overwrite the same device in the system memory you should delete the Bluetooth connection on your mobile device delete the mobile device from the system memory and then register the mobile device in the system memory To register a mobile device enter the programming mode and press VALET button 18 times LED indicator will light green green light indicate...

Page 17: ...torage of event history life is no less than 1 month Mobile apps for Android and iOS You can download mobile apps from your device s app store Google Play App Store To access the app use the login data received from the service at the registration stage Pandora Online Android and control via Bluetooth Being in the coverage zone of the Bluetooth connection Pandora Online can control the system and ...

Page 18: ...on Active security Text messages Tracking Voice calls Interior temperature Fuel remaining in the tank Current coordinates Exterior temperature 13 5V Security mode icon Security and warning zones WWW Trunk Warning zone of the supplementary sensor Alarm zone of the supplementary sensor Warning zone of the shock sensor Alarm zone of the shock sensor Battery power failure Ignition Security mode icon F...

Page 19: ...ct wire 1 of radio relay to the grounding spot Apply power 12V to the contacts 3 and 4 of radio relay The siren Beeper will confirm recording of radio relay to the system s memory with 1 beep Shortly press VALET button to save settings After successful recording of radio relay switch off and insulate contact 3 connect contact 4 to the constant power 12V or to any wire which has constant voltage of...

Page 20: ...anty does not include batteries of the remotes as they have their own service life time Maintenances and repairs of the system with expired warranty period are carried out at the expense of the user on separate contracts between the user and the installer service center Transportation rules Products should be transported in the original packaging by any means of transport as long as they are prote...

Page 21: ...____________ Responsible person s signature stamp Packager______________________________________________________________________ Signature personal stamp WARRANTY CARD Model Pandora DXL 1920L 1930L Serial number _________________________________________________________________ Date of purchase ____ ______________________ 20____year __________________________________________________________________...

Reviews: