7.
Calibration procedures for 03700A
manifold
A flow and pressure test gauge is required for calibrating hydraulic power sources. Pandrol part number 03600
flow and pressure test gauge.
Note: procedures should only be performed after the engine has been warmed and the hydraulic oil has reached
approximately 70-90 degrees (21-32 celsius).
7.1.
Flow calibration
Fig 4.
Connect the 03600 female coupling onto the 10 GPM (male) port, and
the male coupling into the return (female) port. Open top and bottom
control valves and read the flow meter, make certain the needle valve
is open not restricting flow. You should have a reading of 10 GPM. (As
shown)
13 av 34
OPERATION AND MAINTENANCE MANUAL I ENG_OMM_ELECTRIC_POWER_UNIT_P01 I 30th November 2021