Configuration and Management Interfaces
Setting
Description
Baud rate
Sets the baud rate. The following options are available: 2400, 9600, 19200,
38400, 56000, 57600, 115200.
Data bit
Sets the number of data bits used to represent each character of data. The
following options are available: 7 or 8.
Parity
Sets the parity bit, which can be included with each character to detect errors
during the transmission of data. The following options are available: None,
Odd, or Even.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing
the client to detect the end of a character stream. The following options are
available: 1 or 2.
RS-232 Parameter Setting
RS-232 settings for local or HDBaseT RS-232 control.
• RS232 over HDBaseT
If the AT-OME-MS42 is connected to a device such as the AT-OME-EX-RX, the drop-down list boxes will be
disabled and the HDBaseT baud rate will be locked at 115200. If the AT-OME-MS42 is connected to another
HDBaseT device, such as the AT-UHD-CLSO-824, each of these drop-down list boxes can be set to the baud
rate of the HDBaseT RS-232 settings on the corresponding device. Refer to
Solution Setup and Configuration
for more information.
• RS232 Console
Sets the RS-232 port settings used for local control by a third-party control system.
• Save
Click this button to commit all changes.
RS-232 Page
This page provides settings for both local and HDBaseT RS-232 control.