AT-OME-MS42
75
a.
Enter the hexadecimal command string is the correct field. An example
power-on
command for a display
might be:
\xBE\xEF\x03\x06\x00\xBA\xD2\x01\x00\x00\x60\x01\x00\x0D
This command would be entered under the
Set command
field, under
ON
. Consult the documentation for
the display for the correct command strings.
b. Make sure the command string is terminated correctly. In most cases, a CR (carriage return) should be
specified. In the example above, “\x0D” is the hexadecimal value for a carriage return.
HEX Command Strings
ASCII Command Strings
a.
Enter the ASCII command string is the correct field. An example
power-on
command for a display might be:
PWON
This command would be entered under the
Set command
field, under
ON
. Consult the documentation for
the display for the correct command strings.
Solution Setup and Configuration Guide
14. Click the
Send
button to verify that each command works properly. If not, check the values entered for each
command.
15. Click the
Save
button to commit all changes.