background image

INSTRUCTIONS CM408F

For Technical Support: www.panduit.com/resources/install_maintain.asp

Page 13 of 24

Single Hinge Door Handle Direction Reversal

NOTE:  

N

ET

-S

ERV 

cabinet configurations that ship with Single Hinge Doors are hinged on the left side by default.

With single hinge door removed, remove (2) hinge brackets from cabinet frame by removing (2) #10 Phillips screws and (2) #10 lockwashers 
from each bracket and slide bracket out of cabinet frame as shown.  Invert brackets so that bottom-left bracket becomes top-right bracket and 
top-left bracket becomes bottom-right bracket as shown below.  Secure brackets to cabinet post with (2) #10 Phillips screws and (2) #10     
lockwashers per bracket.  Brackets are to be inserted through upper-most opening of cabinet frame.

Reverse door handle orientation by removing cam from door handle assembly and door handle assembly from Single Hinge Door.  Rotate door 
handle assembly 180º.  Rotate orienation of cam stop 90º clockwise while door handle cam and hex bolt are removed from handle assembly.  
Reinstall handle assembly into Single Hinge Door.  See ‘Door Handle Direction Reversal’ view below.  Remove PANDUIT label from bottom of 
door and reinstall label centered and 7-1/4” from top of door.

#10 Phillips Screws and 
#10 lockwashers

(Remove and use to install 
hinge bracket on opposite 
side of cabine frame)

Hinge Bracket

(Tab is to be inserted 
into cabinet frame)

Hinge Bracket Installation and Removal

Door Handle Direction Reversal

FRONT OF CABINET

Remove Hinge Brackets

(See detail view)

Reinstall Hinge Brackets on 
Right Cabinet Post

(Hinge point to be orientated 
towards outside of cabinet)

Remove Door Handle Cam 
and Hex Bolt

Remove Phillips Screw and Bridge Bar

Remove Door Handle, Rotate 180º, and Reinstall Handle

Reinstall Door Handle Cam 
and Hex Bolt

Reinstall Phillips Screw and Bridge Bar

Rotate Orientation of Cam 
Stop 90º Clockwise

(This allows for door 

handle to swing in 

proper direction)

Summary of Contents for NET-SERV Series

Page 1: ...INSTRUCTIONS CM408F Panduit Corp 2009 2011 FOR TECHNICAL SUPPORT www panduit com resources install_maintain asp NET SERV Cabinets Page 1 of 24 ...

Page 2: ... Hinge Door Handle Direction Reversal 13 Split Doors 14 Side Panel Installation 15 POU Mounting Brackets 16 POU Mounting Bracket Locations 17 Vertical Patch Panel Bracket Installation 18 Overhead Cable Openings 19 Vertical Exhaust Duct Mounting 20 Cabinet Sealing 21Ͳ23 Page 2 of 24 NOTES Casters can support a fully loaded cabinet However the casters should only be used to move the cabinet from one...

Page 3: ... S22PS S52PS Casters SCSTR POU Brackets SVPDUB Cage Nut Equipment Rails and Brackets S62RC S65RC S72RC S75RC Cable Management Finger Bracket and Fingers S62BRFK S65BRFK S72BRFK S75BRFK Cable Management Panel and L Retainers S62BRCK S65BRCK S72BRCK S75BRCK Vertical Patch Panel Bracket SVPPB 6 L Fingers and 1 CMSRC2 are included per panel ...

Page 4: ... the base rails in the locations shown to adjust legs until the cabinet is level For ganged cabinet applications ensure that adjacent cabinets are adjusted to the same height parallel with each other and no gaps at the top or bottom between cabinets 3 8 socket Note The maximum weight load of the cabinet is 2500 pounds 1134 kg The weight load should be evenly distributed across the height of the ca...

Page 5: ...Leveling the cabinet prior to ganging is important to ensure proper door operation Secure the cabinets with two 2 top ganging brackets and 2 bottom ganging brackets with two 2 10 32 trilobular screws per bracket in the locations shown 10 32 Trilobular Screw Ganging Bracket 10 32 Trilobular Screw Ganging Bracket IMPORTANT Ensure tops of cabinets are touching prior to ganging Do not cinch the cabine...

Page 6: ...he concrete slab or threaded rod via the included anti tip brackets Assembly Sequence 1 Install the anti tip brackets to the inside of cabinet frame using 2 5 16 bolts 1 2 socket per bracket as shown below Brackets are slotted to allow for raising and lowering of cabinet See leveling instructions on Page 4 2 Attach the anchors to the floor with appropriate hardware for your type of floor See Floor...

Page 7: ...elow Remove masking from desired grounding location see detail below Attach grouding lug with 2 12 24 screws Grounding jumpers are pre installed between cabinet frame and rear split doors and are included in all NET SERV configurations that ship with split doors installed on cabinet Grounding Lug Locations Grounding Lug Location Detail Remove masking and attach grounding lug with 2 12 24 screws ...

Page 8: ...m of equipment rail bracket to release clamping pressure to allow for front to back rail adjustment Reposition rails and tighten 4 5 16 bolts to 14ft lbs 19 0 N m Bottom Location Loosen 2 5 16 Bolts to release clamping pressure for front to back rail adjustment use 1 2 socket Loosen 2 5 16 Bolts to release clamping pressure for front to back rail adjustment use 1 2 socket Equipment Rail Bracket Eq...

Page 9: ...osition bracket and secure cable management bracket with 4 12 24 hex head screws as shown Cable management fingers may be placed where desired by inserting the tabs on the rear of the finger sections into the mounting slots located on the cable management brackets and then sliding downward Reverse the process to remove cable management fingers Loosen 2 12 24 Hex Head Screws for precise bracket adj...

Page 10: ...MSRC2 bend radius control clip can be installed in any of 6 indicated locations with 2 12 24 Phillips screws as shown Cable Management L Retainers are to be installed where desired by inserting the tab on the rear of the L Retainer into any keyed mounting slot located on the cable management panel and then sliding downward while pulling release tab forward as shown Pull release tab and reverse the...

Page 11: ...s Position bottom blanking panel over base frame of cabinet and secure with 10 Phillips screws and lockwashers as shown below To adjust depth of vertical blanking panels loosen 6 10 Phillips screws on each vertical panel adjust panels to desired depth and retighten 12 10 Phillips screws To Adjust Loosen 12 10 Phillips Screws on each vertical blanking panel 6 screws per side 10 Phillips Screws and ...

Page 12: ...ng bracket Align upper hinge pin with upper door mounting bracket Position door into place and pull down the lever of the spring loaded hinge pin and release lever when door is aligned Reverse steps to remove the door Note Make sure that both pins are fully engaged when door is installed Upper Door Mounting Bracket Upper Hinge Pin pull lever down Lower Hinge Pin Lower Door Mounting Bracket ...

Page 13: ...Single Hinge Door Rotate door handle assembly 180º Rotate orienation of cam stop 90º clockwise while door handle cam and hex bolt are removed from handle assembly Reinstall handle assembly into Single Hinge Door See Door Handle Direction Reversal view below Remove PANDUIT label from bottom of door and reinstall label centered and 7 1 4 from top of door 10 Phillips Screws and 10 lockwashers Remove ...

Page 14: ...ounding jumpers are located near bottom of doors Close split doors and remove 4 hinge pins hinges include a safety feature that keeps doors captive unless they are open to 90 Open each split door to 90 and slide door away from cabinet and out of hinges Reverse steps to reinstall split doors Disconnect 2 Grounding Jumpers Remove 4 hinge pins from split doors With split door open to 90 slide door ou...

Page 15: ...frame Lower the side panel until the mounting hook is seated on the bottom side panel bracket and the panel is resting on the cabinet frame Rotate the side panel into place until the panel is flush with the cabinet frame and the 2 latches engage Pull down on the 2 latches to disengage the side panel then rotate and lift the panel to remove Pull down and release latches Side Panel Mounting Hook Bot...

Page 16: ...to cabinet frame reposition brackets and secure each bracket to cabinet frame with 2 12 24 hex head screws Tabs on brackets are to be inserted into cabinet frame as shown NOTE When reinstalling POU brackets to cabinet bracket with diamond cutout is to be mounted at top of cabinet Loosen 2 12 24 Hex Head Screws for precise bracket adjustment use 5 16 socket Loosen 2 12 24 Hex Head Screws for precis...

Page 17: ...INSTRUCTIONS CM408F For Technical Support www panduit com resources install_maintain asp POU Mounting Bracket Locations Page 17 of 24 MAX MIN MAX 1 RU 1 75 ...

Page 18: ...head screws into tapped holes of vertical support of vertical patch panel as shown Screws are to pass through slots in finger bracket to engage vertical patch panel bracket and allow for vertical adjustment of bracket NOTES SVPPB to be used with finger bracket only 700mm 28 Recommend use with Panduit Pan Net and Quick Net 1 Rack Unit Patch Panels 3 SVPPB may be fitted to a 42 RU 700mm 28 cabinet 4...

Page 19: ...ry The bezel inserts can be removed from overhead cable opening bezels by pulling inserts out of position Bezels can be removed from cabinet top by depressing tabs and pulling out of position The remaining knock outs can be removed by cutting the 8 tabs with a wire cutter as shown Additional bezels and bezel inserts are available for purchase Removable Bezel Inserts Overhead Cable Opening Bezel ...

Page 20: ...nd 4 10 lockwashers holding upper duct to lower duct Raise upper duct to desired height and secure using 4 10 Phillips screws and 4 10 lockwashers 2 additional screws and lockwashers are on rear of duct Fine Duct Adjustment Top Collar Loosen 4 10 Phillips screws holding top collar assembly in place Position top collar so that seals are secure against ceiling and slightly compressed Retighten 4 10 ...

Page 21: ...alled Apply top seal behind grounding clips Use ganging brackets to maintain firm contact of bulb seals see page 5 Side panel must be removed to install foam seals See Cabinet Post Section View CABINET WITH SIDE PANEL adjacent to CABINET WITH SIDE PANEL Cut 4 pieces of thin adhesive foam seal to length and attach along flanges in side panel opening of each cabinet where side panels are installed A...

Page 22: ... 2 Phillips trilobular screws and paint piercing washers per bracket Foam seals are to sit under the cabinet frame when installed Lower and level the cabinet frame to between 1 2 and 1 above floor to maintain a firm seal between cabinet frame and floor NOTE SFS KIT is required for end of row floor sealing 2 10 32 x 1 2 Phillips Trilobular Screws and Paint Piercing Washers Floor Seal Bracket Floor ...

Page 23: ...t Door Catch Blanking Panel is to be adjusted upwards to blank both door catch openings New position is indicated by dashed lines Left Door Catch Blanking Panel is to be adjusted upwards to blank upper door catch opening only New position is indicated by dashed lines Right Door Catch Blanking Panel Adjust upwards so that both door catch openings are blanked LEFT DOOR CATCH BLANKING PANEL RIGHTDOOR...

Page 24: ... CM408F For Instructions in Local Languages and Technical Support www panduit com resources install_maintain asp E mail cs panduit com Fax 708 444 6448 www panduit com Page 24 of 24 THISPAGEISLEFTBLANKINTENTIONALLY ...

Reviews: