INSTRUCTIONS CM315E

For Technical Support: www.panduit.com/resources/install_maintain.asp

Kit Contents

Combination locks (2)

Spacer rings (2)

Cylinder nuts (2)

Retaining screw (2)

Lock washers (2)

Flat washers (2)

Direction setting washers (2)

Cam Lock Spacer 
Rings

Combination locks 
including Cylinder Nut, 
Retaining Screw, Lock 
Washer, Flat Washer and 
Direction Setting Washer

Figure 1

Cam Lock Spacer 
Rings

Combination locks 
including Cylinder Nut, 
Retaining Screw, Lock 
Washer, Flat Washer and 
Direction Setting Washer

Figure 1

.640
.650

.755
.765

 DIA.

Mounting Cutout

Installation

Remove the existing locks from the cabinet and save 
cams for later use. (Figure 2)

Remove the Cylinder Nut from the Combination Lock 
and insert the Spacer Ring over the Lock Cylinder. 
(Figure 3)

Install the Combination Lock onto the Cabinet and 
tighten the Cylinder Nut. The Lock Head should be 
spaced away from the Cabinet Surface. (Figures 3 & 
4)

Remove the Retaining Screw, Lock Washer, Flat 
Washer, and Direction Setting Washer.

Pull the Lock Head from the cylinder and rotate until 
oriented in the desired direction. (Figures 5-7)

Figure 2

Cam
from 
lock

Figure 3

Cylinder Nut

Spacer Ring

Combination Lock Head

PZWMC* Cabinet 
Surface

Lock 
Cylinder

Cylinder Nut 
Installed on 
Back of Cabinet

Figure 4

Figure 5

Spacer RIng

Lock 
Head

Figure 6

Cam will 
rotate 
right

Cam will 
rotate left

Direction Setting Washer

Figure 7

Page 8 of 11

P

AN

Z

ONE

 Lock Kits (PZWMC-CL)

Summary of Contents for PANZONE PZWMC

Page 1: ...tprint with Cabinet Open 25 0 Cabinet Width PANZONE Wall Mount Cabinet Part Numbers PZWMC Location Footprint PZWMC12W Cabinet with Windowed Door Parts Included 1 Extra Door Spacer 8 Keys 1 Roll of Tak...

Page 2: ...om wall and tighten the hardware securely Re install door and side panels Door swing direction can be changed by rotating the door 180 Ensure the plastic spacer is placed at the bottom of the door hin...

Page 3: ...net Jumper Grounding Kit Only 2 Recommended for direct 1 1 switch patching only 3 Recommended for direct 1 1 switch patching only 4 Default Rail Location Recommended for traditional patching with smal...

Page 4: ...k loop to prevent cable damage Route cable to point 1 secure to tie down with a TAK TY Next route cable across the bottom of the enclosure to point 2 secure to tie down with a TAK TY Route to the desi...

Page 5: ...uipment Rail Kits PZCHSM2 PANZONE Horizontal Slack Manager PZWMC12W Shown Cabinet with Window Door PZBR3 5 PANZONE 3 5 Bend Radius Post Kit PZCFK PANZONE Fan Kit PZBR3 PANZONE 3 Bend Radius Post Kit P...

Page 6: ...rio 1 Switches not exceeding 120 watts of total heat output use fan kit as shown Scenario 2 POE Power over Ethernet or switches totaling over 120 watts of total heat use two PZCFK fan kits or one PZWM...

Page 7: ...on for optimal mounting location s Screw Mounting Locations Figure 3 Bend Radius Post Installation Bend radius posts can be installed at any rack location using 1 12 24 x 2 5 1 12 24 x 1 5 for PZBR3 s...

Page 8: ...et and save cams for later use Figure 2 Remove the Cylinder Nut from the Combination Lock and insert the Spacer Ring over the Lock Cylinder Figure 3 Install the Combination Lock onto the Cabinet and t...

Page 9: ...ous lock Flat Washer Lock Washer and Retain ing Screw Figure 7 Set the lock to the factory combination 0 0 0 Test lock rotation direction Adjust cam angle if necessary To Change Combination Set the l...

Page 10: ...f 24 Port Patch Panels PZCHSM2 PZCHSM2 2 RU of Active Equipment 2 RU of Active Equipment 2 RU of Active Equipment PZCHSM2 PZCHSM2 PZCHSM2 2 RU of 24 Port Patch Panels 2 RU of 24 Port Patch Panels 2 RU...

Page 11: ...mended Mounting Locations for Bend Radius Posts Never cross over center line of horizontal slack manager with cable slack Typical patch cord length is 4 feet minimum Route patch cords as shown to avoi...

Reviews: