PAT1M / PAT1.5M OPERATION MANUAL
PAT1M/PAT1.5M: PA22222A01_03
Page: 10 of 36
Dec., 2007
The "Escape" button can be pressed to go directly to Level 1 or 1B Operator Menus (Refer to the
Cable Tie
Installation
section on Pages 13-14). It is important to note that the tool will only cycle cable ties when the
display is returned to the Level 1 or 1B Operator Menus ("Load, Unload, Menu" Display).
2. Press
the
"MENU"
button to bring up the Level 2 menu:
LEVEL 2 - Load and Counter Reset Menu ("Reset" Display)
Resets load and/or counter
Reset Ld
Reset Ct
Exit
The
"Reset Ld"
button will return to the last menu level (Level 1) while also resetting the Load counter back to
"14". This allows the unit to be reloaded (To reload the dispenser, follow the Reloading Procedure on Page 9).
Pressing the
"Reset Ct"
button will zero the "resettable counter" on the Level 1 menu.
There is not a
"MENU"
button in this level (Level 2) since it is the last menu level for operator use. The following
procedure is for lead person or setup person only.
The
"Exit"
button will return to the last menu level (Level 1). If ONLY the "Exit” button is pressed, the load
counter and or the "resettable counter" will remain unchanged. See Step 1.
-------------------------------------------------------------------------------------------------------------------------------------------------
3. The display at Level 2 does not show a "Menu" selection at the third button. The Setup menu levels (Level 3 thru
Level 6) are not required except to set, or to adjust the unit, and are reached by the following sequence:
a. Verify that the Level 2 menu is on the display.
b. Press the second button from the right, two times, followed by pressing the button on the far left, one (1)
time.
LEVEL 3 - Total Counts Menu (Dispenser and Tool)
Shows total counts
Counters
Escape
Menu
Exit
IMPORTANT!! Please note that once you press the "Escape" or "Exit" button to return to menu Level 1,
1B, or 2, you must repeat the sequence (Steps 3.a. and 3.b.) to re-enter the higher menu
levels (Level 3 thru Level 6).
Press the
"Counters"
button to view the total count to date for the PDM Dispenser and the PAT1M or PAT1.5M
Tool. Pressing this button will bring up the following display:
LEVEL 3A
PDM
# XXXXXX
Rev X.X
Cycles: XXXXXXX
PAT1M # XXXXXX
Cycles: XXXXXXX
The number (XXXXXX) to the right of each component is the serial number of the particular component. The
number (X.X) to the right of "Rev" represents the revision level of the software for the system. The number
(XXXXXXX) to the right of "Cycles" represents the number of times the particular component has been cycled.
These total counts are not resettable. Press Button 4 to return to the last menu level (Level 3).
Press the
"Escape"
button to return directly to Level 1 or 1B (Operator Menus). See Step 1.
Press the
"MENU"
button to advance to the next menu level (Level 4). See Step 4.