PAT1M / PAT1.5M OPERATION MANUAL
PAT1M/PAT1.5M: PA22222A01_03
Page: 5 of 36
Dec., 2007
TECHNICAL SPECIFICATIONS
AIR SUPPLY
ITEM DESCRIPTION
Recommended regulated air pressure to dispenser
(pressures other than recommended may result in
unsatisfactory operation):
Regulator settings: 65 PSIG (4,5 bar) with a max. 10
PSI (0,7 bar) drop.
DO NOT EXCEED 85 PSIG (5,8 bar).
Air consumption at 25 cycles per minute:
7 cfm @ 65 PSIG (3,3 l/sec @ 4,5 bar)
Line pressure to regulator:
Minimum 70 PSIG (4,8 bar),
Maximum 125 PSIG (8,5 bar)
Filter/regulator requirements:
40 micron maximum element rating, 5 PSI (0,3 bar)
maximum pressure drop @ 70 PSIG (4,8 bar) inlet
pressure and 12 cfm (5,7 l/sec) flow minimum.
Lubrication for air supply:
Air line lubricators are NOT to be used.
Recommended filter/regulator unit (supplied by user)
3/8" NPT ports:
Recommended source:
PANDUIT
Part Number PL283N1 (See Page 3).
Recommended main air supply hose from filter/regulator
to dispenser (supplied by user):
Recommended source:
PANDUIT
Part Number PDH10-37 (See Page 3).
Recommended female quick disconnect for main air
supply (supplied by user): The dispenser is furnished
with a male quick connect plug that will fit the listed
female interchangeable couplers or their equivalents.
Recommended source:
1. Truflate type 2 & 4, 1/4" couplers
2. Hansen series 1000 & 3000 couplers
3. Foster series 3 & FM3, 1/4" couplers
4. Snap-tite series 31 couplers
5. Daisen Couplings 22-SH (Japan)
6. Obac Corporation, Series 25 (Germany)
ELECTRICAL SPECIFICATIONS
ITEM MODEL
DESCRIPTION
Line Voltage (PDM Dispenser)
All
100 / 115 / 230 V
(50/60 Hz)
Power All
300
W
Phase All
Single
Phase
Line Fuse(s)
All
F 4 A, 250 V (2) -
PANDUIT
# CA21138A01
Power to Tool
All
Logic -- 5 V , 50 mA
Motor -- 36 V , 1A (mean)
KPDM1
Germany, Austria, France, Belgium, Luxembourg, Spain,
East Europe
KPDM2 Italy
KPDM3 UK, Singapore, Ireland
KPDM4 Australia,
Argentina
International Use Kits
(purchased separately)
Each includes the specific power cord set
for the country of use and the universal
conversion air disconnect (KPDM1 and
KPDM2 include system operation
manuals in the primary language of those
countries)
KPDM5 Japan
This unit includes EMI/RFI filters, however it is possible that infrequent electrical phenomena may cause tool function to be