© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 51 of 64
12-2018
10: MAINTENANCE
10A: Daily Preventive Maintenance
The following maintenance of the PAT1M4.0/PAT1.5M4.0 Systems must be performed daily (as needed) to
ensure optimum performance and trouble-free operation of the system.
INTERVAL
MAINTENANCE PROCEDURE
No more than 300 cycles
Empty tool tip collector before full.
(Refer to the
Tip Collector
section on Page 22.)
No more than 2500 cycles
(= ½ cable tie reel)
Empty dispenser carrier strip scrap bin.
(Refer to the
Reloading Procedure
section on Page 19.)
10B: Extended Maintenance
CAUTION: SAFETY GLASSES WITH SIDE SHIELDS MUST BE WORN AT ALL TIMES
DURING THE MAINTENANCE OR ADJUSTMENT OF THE PAT1M4.0 / PAT1.5M4.0 TOOLS.
CAUTION: ALWAYS DISCONNECT AIR SUPPLY FROM TOOL BEFORE DISASSEMBLY.
CAUTION: ELECTROSTATIC SENSITIVE DEVICE. DO NOT OPEN OR HANDLE EXCEPT AT A
STATIC FREE WORK STATION.
The following maintenance of the PAT1M4.0/PAT1.5M4.0 Systems must be completed within the recommended
intervals to ensure trouble-free operation and longevity of the system. Certain extended maintenance procedures
must be performed by your maintenance department. Please notify your maintenance department when these
specific maintenance intervals are reached.
1. Disconnect the PHM Feeder Hose
from the PAT1M4.0 or PAT1.5M4.0
Tool. Remove the tip collector from
the tool.
Fig. 20
2. Place the tool on a table top with the
jaws to the left. Using a 2.5 mm hex
wrench, remove the five (5) socket
head cap screws from the left hand
housing. Make note of the correct
locations for each of the screws using
Fig. 20.
3. Perform the following maintenance
procedures shown below at the
prescribed interval:
ITEM
QTY
SIZE
1
2
M3 x 25
2
3
M3 x 8
Summary of Contents for PAT1M4.0