© Panduit Corp. 2018
OPERATION MANUAL
ENGLISH
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
PA27647A01_05
Page: 56 of 64
12-2018
MESSAGE
POSSIBLE CAUSE
CORRECTIVE ACTION
ERROR 06
Tie in tool
Cable tie reaches the tool but is
prevented from completing the
cycle due to a large air pressure
drop, too large of a bundle,
improper feeder hose connections,
an obstruction blocking the cable
tie path, a severe bend or twist in
the feeder hose, or the tool jaws
are opened during the cycle.
1. Press “Silence” icon to silence the alarm.
2. Remove cable tie and any obstruction from the jaw area.
3. Press the "Back" icon to resume operation.
4. Correct any conditions that prevent the cable tie cycle from being
completed.
MESSAGE
POSSIBLE CAUSE
CORRECTIVE ACTION
ERROR 07
Tie in hose - press air
burst
Cable tie is caught or remains in
feeder hose upon actuation due to
a severe bend or twist in the feeder
hose, low air pressure, or an
interrupted cycle.
1. Press “Silence” icon to silence the alarm.
2. Straighten feeder hose to eliminate any bends or twists, and
point tool away from yourself and others.
3. Press "Air burst" icon to dislodge and advance cable tie to
jaw area of tool. Press several times, if necessary. When
cable tie is advanced to jaw area, "Tie in tool" message will
appear and buzzer will sound.
4. Press “Silence” icon to silence the alarm.
5. Remove cable tie from jaw area and press the "Back” icon.
6. Press "Load" icon to load one (1) cable tie and resume
operation.
7. If the cable tie does not advance to the tool jaw area after
depressing the "Air Burst" icon several times, replace the
feeder hose with another and notify your maintenance
department.
ERROR 08
Blocked hose - failed
back pressure test
Tool was actuated while a cable tie
was still in the feeder hose.
Follow corrective action for "Tie in hose - press air burst" error
above.
ERROR 09
Blocked or dirty exit
sensor
Exit (optical) sensor in the
dispenser is obstructed due to a
cable tie or excess debris (dirt,
grime).
1. Press “Silence” icon to silence the alarm.
2. Disconnect feeder hose from dispenser. Look for cable tie
in dispenser connector block and remove cable tie, if
present.* Reconnect feeder hose, and resume operation. If
cable tie is not found, reconnect feeder hose. Follow the
same Corrective Action for "Tie in hose - press air burst"
error to remove the cable tie from the system.
3. If the same error is repeated, clean the dispenser exit
sensor lens (Refer to the
Cleaning the Dispenser Exit
Sensor Lens
section on Page 53).
ERROR 10
Blocked or dirty tool
sensor
Tool (optical) sensor is obstructed
due to a cable tie or excess debris
(dirt, grime).
1. Press “Silence” icon to silence the alarm.
2. Disconnect feeder hose from tool. Look for cable tie in tool
or tool end of hose and remove cable tie, if present.
Reconnect feeder hose, and resume operation. If cable tie
is not found, reconnect feeder hose. Follow the same
Corrective Action for "Tie in hose - press air burst" error to
remove the cable tie from the system.
3. If the same error is repeated, the tool sensor lens may
require cleaning. Contact your maintenance department to
have the tool sensor lens cleaned.
ERROR 11
Tie stuck in exit
sensor obstructed
The dispenser exit sensor in is
blocked so that a cable tie cannot
exit the dispenser. It may be
blocked by another cable tie that
was not removed from an earlier
cycle.
1. Press “Silence” icon to silence the alarm.
2. Disconnect air hose and feeder hose from dispenser. Look
for cable tie in dispenser connector block and remove cable
tie, if present.* Reconnect air hose and feeder hose, and
resume operation. If cable tie is not found, reconnect air
hose and feeder hose. Follow the same Corrective Action
for "Tie in hose -press air burst" error to remove the cable
tie from the system.
3. If the same error is repeated, clean the dispenser exit
sensor lens (Refer to the
Cleaning the Dispenser Exit
Sensor Lens
section on Page 53).
Summary of Contents for PAT1M4.0