Preventive Maintenance 

The following maintenance of the PAT4.0 Family Tool  Systems (PAT1M4.0, PAT1M4.0-BT,  PAT1.5M4.0  and 
PAT1.5M4.0-BT) must be performed daily (as needed) to ensure optimum performance and trouble-free operation of 
the system.   

 

INTERVAL 

MAINTENANCE PROCEDURE

 

No more than 300 cycles

 

Empty tool tip collector before full.

  

No more than 2500 cycles

 (= ½ cable tie reel) 

Empty dispenser carrier strip scrap bin.

 

 
 

 

CAUTION: SAFETY GLASSES WITH SIDE SHIELDS MUST BE WORN AT ALL TIMES 

DURING THE MAINTENANCE OR ADJUSTMENT OF THE PAT4.0 FAMILY OF TOOLS. 

 

CAUTION: ALWAYS DISCONNECT AIR SUPPLY FROM TOOL BEFORE DISASSEMBLY. 

 

CAUTION: ELECTROSTATIC SENSITIVE DEVICE. DO NOT OPEN OR HANDLE EXCEPT AT A 

STATIC FREE WORK STATION. 

 
 

The following maintenance of the PAT4.0 Family Tool Systems must be completed within the recommended intervals 
to ensure trouble-free operation and longevity of the system.  Certain extended maintenance procedures must be 
performed by your maintenance department.  Please notify your maintenance department when these specific 
maintenance intervals are reached. 

 

1.  Disconnect the PHM Transfer  Hose 

from the PAT4.0  tool  system.    
Remove the tip collector from the tool. 

 

Fig. 1

 

2.  Place the tool on a table top with the 

jaws to the left.  Using a 2.5 mm hex 
wrench, remove the five (5) socket 
head cap screws from the left-hand 
housing.  Make note of the correct 
locations for each of the screws using 
Fig. 1. 

3.  Perform the following maintenance 

procedures shown below at the 
prescribed interval: 

ITEM 

QTY 

SIZE 

M3 x 25 

M3 x 8 

 
 
 