CORRECTIVE ACTION:
Press the
"Buzzer"
button to turn the buzzer signal "off". If the reel is empty, press the
"Continue"
button, and then the
"MENU"
button, to bring up the "Reset" display. Press the
"Reset load"
button to
bring up the "Load, Unload, Menu" display and perform the standard reloading procedure (Refer to the
Reloading
Procedure
section on Page 13). If this message appears, and it is apparent that the reel is not empty, then the tool
was cycled without enough cable ties loaded, or a cable tie was prevented from leaving the dispenser. A cable tie will
remain in the dispenser due to little or no air pressure, or an obstruction. In all cases, disconnect the air hose and
feeder hose from the dispenser. If a cable tie is in the connector block, and it can be removed; do so. If a cable tie is
not seen, contact your maintenance department to prevent further complications. After the cable tie is removed,
reconnect the air hose and the feeder hose to the dispenser. Press the
"Continue"
button, and then the
"MENU"
button, to bring up the "Reset" display. Press the
"Reset load"
button to bring up the "Load, Unload, Menu" display.
Press the
"Load"
button to load at least one cable tie into the dispenser. Continue system operation.
PREVENTION:
To prevent this problem from recurring, verify that the air pressure is between 65 and 85 PSIG (4,5
and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
ERROR 2 - Cover is open, no tie loaded
Cover is open, no tie loaded
Load
Unload
MENU
Buzzer
POSSIBLE CAUSE:
This message will be displayed if the cover was open and the "Load" button was pressed or the
tool was cycled.
CORRECTIVE ACTION:
Press the
"Buzzer"
button to turn the buzzer signal "off". Close the cover. The rotary
receiver will not advance unless the cover is closed. If the tool was cycled with the cover open, press the
"Load"
button to load one cable tie and resume operation. If the dispenser was being loaded, resume loading.
PREVENTION:
Keep the cover closed.
ERROR 3 - Check for low air pressure
Check for low air pressure
Load
Unload
MENU
Buzzer
POSSIBLE CAUSE:
This message will be displayed if the incoming air pressure is too low, or not connected.
CORRECTIVE ACTION:
Press the
"Buzzer"
button to turn the buzzer signal "off". Increase the air pressure to 65
PSIG (4,5 bar).
PREVENTION:
To prevent this problem from recurring, verify that the air line is connected, and the air pressure is
between 65 and 85 PSIG (4,5 and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
ERROR 4 - Check for high air pressure
Check for high air pressure
Load
Unload
MENU
Buzzer
POSSIBLE CAUSE:
This message will be displayed if the incoming air pressure is too high.
CORRECTIVE ACTION:
Press the
"Buzzer"
button to turn the buzzer signal "off". Decrease the air pressure to
below 85 PSIG (5,8 bar).