background image

FIGURE 1:

1.  Operator  should  manually

wire  the  required  TG  style
Jack Wire Cap for the desired
application.  Wires  must  be
separated  and  slightly  down
over  the  individual  pocket
divider  wedges.  Depress
strain  relief  collar  to  secure
cable.

MADE IN COSTA RICA

TGJT

PA25217A01

Rev. 03  2-2016

OPERATING INSTRUCTIONS

© Panduit Corp. 2016

Page: 1 of 2

FIGURE 2:

2.  Insert the prepared Wire Cap

into  the  Wire  Seating/Cutting
side  of  the  TGJT  Tool.  This
side  pocket  properly  aligns
and  holds  the  prepared  Wire
Cap  in  place.  Make  sure  all
twisted  pairs  of  wires  are  out
to  the  sides  of  the  Wire  Cap
for  proper  cutting  (refer  to
Figure  1).  The  ramp  of  the
Wire  Cap  must  be  pointing
upward  and  be  inserted
into the groove in the upper
Cutter Blade Anvil.

FIGURE 3:

3.  Pull the handle and the mechanism seats the conductors into

the  Wire  Cap.   At  the  same  time,  the  Cutter  Blades  trim  the
wires nearly flush with the side faces of the Wire Cap.

4.  Keeping the handles closed, slide the Wire Cap up and out of

the tool. All wires should cut cleanly.

www.panduit.com

Technical Support: Panduit USA

888-506-5400, Ext. 86914

E-mail:  techsupport@panduit.com

NOTE:  STRIPPED  WIRES  MUST  BE  LONG  ENOUGH  TO

STICK  OUT  OF  THE  SIDES  OF  THE  WIRE  CAP.
Refer to product installation instructions listed above
for recommended wire strip lengths.

RAMP

ANVIL GROOVE

NOTE:  IF THE WIRES DO NOT CUT CLEANLY OR THE WIRE

CAP DOES NOT WANT TO COME OUT, EXAMINE THE
CUTTER  BLADE  EDGE  SURFACES  AT  THE  NEXT
OPENING  CYCLE.    IF  BLADES  ARE  NICKED  OR
APPEAR WORN, REPLACE THEM WITH THE BLADE
REPLACEMENT KIT.

TGJT TOOL

DIVIDER
WEDGES

Refer to product installation instructions for

TX6 PLUS and TX5e UTP Jack Modules: PN403M

and TX6A 10Gig UTP Jack Modules: PN511E

for wiring instructions.

STRAIN
RELIEF
COLLAR

TG STYLE JACK TERMINATION TOOL

FOR INSTALLING ALL

TG STYLE COPPER JACK MODULES

Part No.: 

TGJT