BA_PH_3V_EN_07-22.docx
29
8.4
Machine Installation
•
A foundation is not required. The floor must have a load-bearing
capacity corresponding to the weight of the machine.
•
Before the machine is placed completely on the floor, the four
feet (
S
) supplied must be fitted in the holes provided in the base
plate.
•
An M20 threaded bolt with adjusting nut is attached to each
stand. With a suitable open-end spanner, the machine must be
properly aligned with a machine spirit level 0.1 mm / 1 m.
Figure 9: Adjustable feet
•
Ensure that there is sufficient space around the machine. We therefore recommend allowing a free space of
at least 1.5 m on all four sides when placing the machine.
•
For safe operation of the machine, the floor of the installation site must have a load-bearing capacity of at
least 1500 kg/m
2
.
•
The bare parts of the machine are greased to protect them from corrosion. Carefully degrease the parts
protected against rust with petroleum or benzine.
Be aware of possible crushing hazards when placing the machine (from the pallet to the
floor) by means of a forklift truck or overhead crane. Pay particular attention to your
hands and feet and wear safety shoes and protective gloves as a precaution.
Danger to life when using a forklift truck! Keep a sufficient distance from the forklift
truck and watch its speed. Vehicles with combustion engines also produce toxic ex-
haust gases. Wear a breathing mask if necessary.
It is essential that the machine is level! Check with spirit level!
Dispose of the packaging material in an environmentally friendly way!
Do not use nitro thinner for cleaning. Painted surfaces of the machine can be damaged.
Fire hazard! Do not smoke and do not light an open fire.
8.5
Temporary Storage
If the machine is not put into operation immediately after delivery, it must be stored carefully in a protected
place. Carefully cover the entire machine so that neither dust nor moisture can penetrate. The bare, non-surface-
treated parts (e.g. the cast iron tabletop) are provided with a preservative. This must be checked regularly for
effectiveness and renewed if necessary.
S