BA_PH_690-200_EN_11-22.docx
58
20.1.8.2
Set Reference Dimension for Pull-Out
•
Move flip stop (
4
) for pull-out (
2
) to position
X
•
Measure the distance between the saw blade and the flip stop (
4
) to the nearest 0.1 mm.
Enter measured dimension:
•
Select the “
pull-out
” with button
A
(see
The symbol (
S
) for the active pull-out (
2
) appears in the top line of the display.
•
Enter the measured dimension as described in section
When the measured reference dimensions are set, perform test cuts and check the cut dimensions again.
Repeat the calibration procedure in case of dimensional deviations.
20.1.9
Sleep-Mode
If the Tele-Digit is not needed for a longer period of time (e.g. over the weekend), the digital indicator can be
set to sleep mode to save the batteries.
•
To do this, clamp both flip stops and press the
B
+
A
buttons simultaneously for approx. 3 seconds.
→
The display briefly shows “
oFF
” and then switches off.
•
To switch the display on again, press button
A
.
Please note that both flip stops are in clamped state. If one of the flip stops is moved during the
sleep-mode, the current position will be lost and the system must be recalibrated (chapter
20.1.10
Fix Error Message “FULL”
Figure 64: Error message FULL
If the error message “
_FULL_
” appears in the display, it can be remedied as follows:
•
Clamp both flip stops so that they cannot be moved.
•
Open the battery compartment (
7
) and remove one of the batteries (power supply off).
•
Press buttons
C
+
B
+
A
simultaneously and reinsert battery (power supply back on).
•
The display must show “
SET-UP
”.
•
Press the left button
C
for 11 times
→
The error message should now be cleared.
1
2