BA_PH_690-200_EN_11-22.docx
70
20.10.1
Adjusting the manual scoring saw
On machines with manual scoring unit 1750 (option), the scoring saw is adjusted using the setting wheels
shown in the figure. These are located on the front of the machine.
Figure 83: Setting wheels for scoring saw
•
Height adjustment:
Adjust the desired height using the setting wheel (
1
)
•
Lateral adjustment:
Adjust the desired position using the setting wheel (
2
)
20.11
Spraying System
For certain applications (e.g. when processing aluminium profiles or composite materials with aluminium con-
tent), the machine can be equipped with a spraying system (minimum quantity cooling lubrication). This can be
ordered under Art. No. 4324.
20.11.1
Special features when using a spraying system
When working with the spraying system, it is essential to wear oil-resistant
gloves, closed, tight-fitting clothing and protective goggles.
If the machine is operated with a spraying system, special care must be taken to ensure adequate extraction.
Under certain conditions, harmful substances can be generated in the spray mist.
The
manufacturer's operating instructions for the spraying system must be observed.
Spray lubricants recommended for aluminium machining:
see enclosed
sheet from the manufacturer.
20.12
Calibration Device
Figure 84:
Calibrator “Zeromaster”
With the optionally available calibrator, the cutting
height can be automatically calibrated to 50.0 mm via
the "Zeromaster function" of the positioning control.
This is especially helpful when using different saw blade
diameters.
Even with re-sharpened saw blades, the exact saw pro-
trusion resp. cutting height is always guaranteed after
the saw blade change.
The detailed procedure for calibrating with the calibra-
tion device is described in section
Note for retrofitting:
The signal line of the calibration sensor is permanently connected to the required evalua-
tion electronics in the control cabinet. If an existing machine is to be retrofitted, the system must be installed
on site by our service technicians.
1
2
There is a health hazard for the lungs and respiratory tract due to the spray mist.
Therefore wear a suitable respiratory mask .