Before using or installing the light fixture, kindly read the instructions and follow safety rules or let the qualified company mount it.

Thank you for choosing the item of company PANLUX s.r.o.

Technical datas

Input voltage: 230V~50Hz
Protection: IP44
Class of protection: I.
Lampholder: R7s
Operating temperature: -20°C ~ 40°C

Safety rules/Instalation

Floodlights V150, V500, V1000, V1500 is suitable to install on solid surface (holder, 
outrigger, wall, etc.)
Floodlights must be fixed with screws with diameter 8mm.
Floodlight should placed in appropriate distance between safety glass and flood-ligh-
ting area - min. 1m (see pic. 1.). It is inconvenient to put any subjects closer than 1m to 
the floodlights.
During selection of the desired place, kindly take in account min. distances as 
per pic. 1 to 5.  
If the floodlight is placed near flammable materials, kindly follow instruction
 as per pic. 4.
For electrical supply is required to use transcriptioned incoming cables min. 3x1mm2, 
cable gland and prepared terminal box.

If the lamp is mechanically damaged, guarantee cannot be allowed.

INSTRUCTIONS

MODEL:

Floodlight

VANA 

Installation

Installation of lighting source

Before installation or changing the lighting source, make sure that the mains supply 
is disconnected and wait until floodlight cools down. Use only recommended linear 
halogen or energy saving lamp (see chart 1.). 
Do not touch halogen lamp with bare hand, it could cause its damage.
Unscrew and open the glass cover, insert lighting source in lampholder, direct it 
to the centre of lampholder. 
Close and screw the cover.

Assembling

(Valid only for portable floodlights DV150, DV500)
Put tube-type base in shape G on black metal clamp. Screw scroll that was 
uncovered with unscrewing the fly nut should be visible through hole of the black 
metal clamp. Screw set of fly nuts through hole into metal clamp and to hole with 
scroll in base with shape G. With loosing of fly nuts and moving of lamp you can set 
the floodlight in desired position. You will fix the position with tightening the cross 
nut.

Notice

Before installation or changing the lighting source, make sure that the mains supply is 
disconnected.
If the safety glass is damaged, change it immediately.
Do not touch the glass, if it is hot.

V150, V500, V1000, V1500
DV-150, DV-500

pic. 1

pic. 2

pic. 4

pic. 3

UM_VANA_100422

Technical datas can be changed without previous noticement.

All rights reserved

pic. 5

V150
V500

V1000
V1500

DV-150
DV-500

150W
500W

1000W
1500W

150W
500W

R-150/78, R7S-10

R-500, R7S-20

R-1000
R-1500

R-150/78, R7S-10

R-500, R7S-20

78mm

118mm
189mm
254mm

78mm

118mm

Model

Wattage

Recommended 

lighting sources

Lampholder 

distance 

pic. 6

chart 1