34
Changing Filters
Your Panoscan MK2 allows the IR blocking filter to be interchanged if desired. The camera is also
designed to allow additional creative filters to be “stacked” if desired. The filter size is a 62mm
standard thread. Not more than 2 filters total are recommended because they can cause internal
reflections and flare.
Never use a polarizing filter on this camera because it may severely distort
the color.
The filter holder is located behind the lens mount so that filters may be used with the
fisheye lens. To gain access to the filter holder first loosen the front plate screws on the front of the
camera. The screws are captive to the front plate so you do not need to unscrew them all the way
out. Just loosen them far enough that the front plate separates freely from the camera body.
When you replace the front plate be sure the red alignment mark on the lens mount goes down
toward the motor. The release button should be on top. (Away from the motor.) Note: The CCD is
aligned to your specific lens mount at the Panoscan lab with the release button on top.
If you put
the front plate on upside down the CCD may not maintain perfect alignment with the fisheye lens
causing a distortion at the top of your spherical images.
Tungsten Panoscan filters are marked with two small engraved dots on the ring.
Daylight Panoscan filters are marked with one small engraved dot on the ring.