PG-1810 Service Manual
PANTECH R&D CONFIDENTIAL
53
6.7.5 Antenna Switch Module with SAW Filter _ TEST CONDITION 2, 3, 4, 5, 6, 7
6.7.5.1.
RX Parat
1. Check to see U301.9 and 11 pin’s Voltage are GND : CP 156
NO Check to see C304, C305, U201 and U301 cold solder,broken,short to the other
PCB pattern or not
If you find out any defect, you replace it
2. Check to see U301.13 pin’s power and one’s power of EGSM(U301.1, 2pin), DCS(U301.3,4 pin),
PCS(U301.5, 6pin) is same : CP 157
NO Check to see U301 cold solder,broken,short to the other PCB pattern or not
If you find out any defect, you replace it
6.7.5.2.
TX Parat
1. Check to see U301.9 and 11 pin’s Voltage are 2.8V : CP 156
NO Check to see C304, C305, U201 and U301 cold solder,broken,short to the other
PCB pattern or not
If you find out any defect, you replace it
2. Check to see U301.13 pin’s power is around 30dBm : CP 158
NO Check to see U202 cold solder,broken,short to the other PCB pattern or not
If you find out any defect, you replace it
CP156
CP157
CP158
Summary of Contents for PG-1810
Page 9: ...PG 1810 Service Manual PANTECH R D CONFIDENTIAL 8 3 4 BLUETOOTH MODULE...
Page 43: ...PG 1810 Service Manual PANTECH R D CONFIDENTIAL 42 CP137 CP138 CP136...
Page 45: ...PG 1810 Service Manual PANTECH R D CONFIDENTIAL 44 CP140 CP139 CP141...
Page 47: ...PG 1810 Service Manual PANTECH R D CONFIDENTIAL 46 CP145...
Page 50: ...PG 1810 Service Manual PANTECH R D CONFIDENTIAL 49 CP147 CP148 CP149...
Page 51: ...PG 1810 Service Manual PANTECH R D CONFIDENTIAL 50 CP150...