TIMED START OPERATION:
To begin the start timer, within 10 seconds of turning off the ignition switch, activate the RF
command to start 2 times. (Press the start button four times). The lights will flash and the siren
will chirp 2 or 4 times. Indicating timed interval mode has been initiated. The vehicle will auto-
matically start every 2 or 4 hours as programmed. To cancel the timed start mode start the
vehicle either by RF or by the ignition key.
Diagnostics:
Enter Bank 3 and turn on selectable feature # 7 as described in the feature selection and
setting section.
Exit the feature selection mode then press and hold the pushbutton valet/program switch
and then turn the ignition switch to the on position.
NOTE:
Diagnostic mode is a temporary mode. Once you have accessed the diagnostic
mode, the unit will pause for two seconds then begin to flash the last stored shut down
code. This code will be displayed three times in succession, then the unit will automati-
cally exit the diagnostic mode.
The parking lights will flash a number of times indicating the reason for the last remote start
shutdown. The light flash indications are as follows:
1 Flash
Run timer expired
2 Flashes
Low or no tach signal (RPM)
3 Flashes
Positive inhibit wire activation
5 Flashes
RF shutdown signal received, or manual start trigger wire reactivated.
6 Flashes
High tach signal (RPM)
7 Flashes
Tach signal has not been learned
8 Flashes
Negative inhibit wire activation
4 PIN DATA BUS PORT (DBI Port)
The 4 pin port located on the side of this module is for proprietary Audiovox data bus interface
modules. These modules are used to access a variety of features in the vehicle which can be as
simple as door trigger inputs, to more complex door lock outputs, or transponder interfaces for
remote starting. DO NOT connect anything to this port other than the Audiovox DBI interface
modules or damage to the Remote Start will occur. All installation instructions for the DBI
modules will be packaged with the individual component along with the proper 4 pin wiring
harness requires to access the data transmit & receive as well as the proper voltage levels for
the interface.
Summary of Contents for PA-620C
Page 5: ...128 9108 5 of 24 Page 5 ...