• Important, please note:

  Sight glass luminaires are specifically designed and solely  
  intended for mounting with or onto flanged sight glass 
  fittings. Under no circumstances should a sight glass 
  luminaire be used as a substitute for the cover flange or the  
  complete sight/light port or as a lid or cover for vessel 
  openings. Luminaires for use in potentially explosive environ- 
  ments must be mounted, installed and serviced by staff who  
  have the relevant qualifications and have been properly 
  trained for this type of work.
 
  Please observe the data set out in the EC type-examination  
  certificate!

• General operating conditions:
 

- Independent of pressure/vacuum inside the vessel

  - Approved for use in Ex environments:
    Gas: Zones 1 and 2; Dust: Zones 21 and 22
  - Approved for use in ambient temperatures of between 
    -20°C and +60°C or +40°C, depending on the lamp power  
    (see type plate and temperature classification parameters).

• Electrical data, general:
 

- Voltage, power, temperature class and protection rating 

    are shown on the type plate.
  - Ex approval acc. to EC type-examination certificate:
    BVS 08 ATEX E 136
     

II 2G Ex de IIC T3/T4/T6/120°C Gb

     

II 2D Ex tb IIIC T80/T120/T130/T195°C Db   

  - The variant with 20 VA built-in transformer is PTC-protected;  
    no fuse replacement necessary.
  - Variants with 50 VA built-in transformer are protected by 
    a micro-fuse (T0.315 A for 230 V/240 V; T0.630 A for 120 V).
  - Power supply: AC or DC, depending on lamp fitted
  - Caution: Only alternating current should be used for 
    luminaires with integrated transformer or high-voltage
  timer.
  - Warning: Over-voltage will cause premature lamp failure!
  - 10% voltage tolerance is admissible.

• Parameters/Temperature classification:  

Lumiglas luminaire USL 07-Ex
 

II 2G Ex de IIC T3/T4/T6/120°C Gb

 

II 2D Ex tb IIIC T80/T120/T130/T195°C Db

F.H.Papenmeier GmbH & Co. KG · division Lumiglas
Talweg 2 · 58239 Schwerte · GERMANY
phone: +49-2304 205-0 · fax: +49-2304 205-206
info.lumi@papenmeier.de · www.lumiglas.de

Installation and Operating Instructions

0158

Type USL 07-Ex

Variant

 

Nom.

Voltage

Ambient temperature range

-20°C 

 T

a  

 +40°C

-20°C 

 T

a  

 +60°C

Without terminal box

*

With terminal box

Without terminal box

*

With terminal box

(230 V/12 V) 20 W   230 

,

2G T6

2D T80°C

2G T6

2D T80°C

(24 V) 20 W

  24 

.

2G T6

2D T80°C

2G T6

2D T80°C

(230 V/12 V) 35 W

230 

,

2G T4

2D T130°C

2G T4

2D T130°C

(240 V/12 V) 35 W

240 

,

2G T4

2D T130°C

2G T4

2D T130°C

(12 V) 50 W

12 

.

2G T4

2D T130°C

2G T4

2D T130°C

2G T3

2D T195°C

(24 V) 50 W

24 

.

2G T4

2D T130°C

2G T4

2D T130°C

2G T3

2D T195°C

(24 V) 50 W FL

24 

.

2G 120°C 2D T120°C

(120 V/12 V) 50 W

120 

,

2G T3

2D T195°C

2G T3

2D T195°C

(230 V) 50 W

230 

.

2G T4

2D T130°C

2G T4

2D T130°C

2G T3

2D T195°C

(230 V/12 V) 50 W

230 

,

2G T4

2D T130°C

2G T4

2D T130°C

(240 V/12 V) 50 W

240 

,

2G T3

2D T195°C

2G T3

2D T195°C

(230 V) 75 W

230 

.

2G T3

2D T195°C

2G T3

2D T195°C

Incl. connecting cable