background image

VISULEX Maki

User’s Manual

Summary of Contents for VISULEX Maki

Page 1: ...VISULEX Maki User s Manual...

Page 2: ......

Page 3: ...ing the camera 10 Control Panel 11 Operating Concept 11 Zoom 12 Key 1 Colour modes 13 Key 2 Lines and Curtains 14 Key 3 Mirroring 16 Key 4 Overview Focus 16 Key 5 LED Light 18 Key 6 Set 1 18 Key 7 Set...

Page 4: ...5 Installation 25 Operation 25 PC Software 27 Installation 27 Operation 27 Hotkeys 30 APPENDIX 32 Service 32 Saftey Advice 32 Service and Maintenance 33 Purpose of the Device 33 General Precautions 34...

Page 5: ...User s Manual is protected by copyright belonging to F H Papenmeier GmbH Co KG with all rights reserved The User s Manual may not be copied in whole or in part without written consent from F H Papenme...

Page 6: ......

Page 7: ...second Smallest fonts will be presented in an easily legible way by means of the optical 30 times zoom Thanks to modern LED technology and to using polarizing filters you will obtain optimum illumina...

Page 8: ...Power supply unit Manual Cross table Table clamp optional Switch box optional Low Vision Controller optional Software optional Address F H Papenmeier GmbH Co KG Talweg 2 58239 Schwerte Germany Intern...

Page 9: ...t the Camera Arm Please position the control panel in a way that you can reach it without any difficulties Connect the PS 2 cable of the control panel to the PS 2 port at the camera arm Note Do connec...

Page 10: ...h direction To the right to the left forward and backward respectively Every direction has got a stop In order to view objects located further away like blackboards please turn the camera head forward...

Page 11: ...n this manual the keys will be described in clockwise direction Operating Concept Performing a short key press will execute a direct function Performing a long key press will set up a value in most ca...

Page 12: ...knob The process will be cancelled if no value has been changed or confirmed during 15 seconds Furthermore the process will be cancelled by pressing any key Thus the old values will be restored Optio...

Page 13: ...erformed the colour saturation can be set By means of the rotary knob you can select the optimum colour saturation according to your needs By pressing on the rotary knob the changed value will confirm...

Page 14: ...etween the following line or curtain types Horizontal lines Horizontal curtains Vertical lines Vertical curtains By pressing on the rotary knob the line or curtain type will confirmed This will lead y...

Page 15: ...he colour of the lines or curtains can be selected By means of the rotary knob you can select the optimum colour according to your needs By pressing on the rotary knob the selected colour of the lines...

Page 16: ...l be flipped vertically in addition Consequently you will obtain a presentation of a mirror Key 4 Overview Focus Overview Perform a short press on key 4 to activate the overview mode This is very usef...

Page 17: ...de is activated you can adjust the zoom to find the area more easily which you wish to magnify Press Key 4 again or press on the rotary knob Colour effects lines or curtains will be set to the previou...

Page 18: ...ight brightness according to your needs By pressing on the rotary knob the changed value will confirmed Key 6 Set 1 By performing a short press on Key 6 the saved settings of set 1 will be loaded By p...

Page 19: ...um brightness according to your needs By pressing on the rotary knob the changed value will confirmed Pseudocolour When Pseudocolour is activated the threshold value of Pseudocolour can be adjusted By...

Page 20: ...f and the image will turn black You are able to exit stand by mode by means of a gesture under the camera by pressing a key or by turning the rotary knob Please note that also small changes of brightn...

Page 21: ...balance Cold Sounds OFF Language English Standby 5 min Info Exit The colour combination of the menu depends on the selected Pseudocolour combination By means of the rotary knob you can move up and do...

Page 22: ...e process please select again NO by means of the rotary knob and confirm this by pressing on the rotary knob You will get back to the previous menu White Balance The on screen menu presents you the fo...

Page 23: ...receive no more acoustical feedback Confirm your selection by pressing on the rotary knob You will get back to the previous menu Language The on screen menu presents you the following line Language En...

Page 24: ...of the rotary knob you can set the time after which the Standby mode is to be activated In order to deactivate the Standby mode turn the rotary knob to the left until you read OFF Confirm your selecti...

Page 25: ...Output to the monitor Operation Use the keys on the low vision controller to control the the switching or mixing of the images In the following you will be given a short instruction to the most impor...

Page 26: ...ivate split screen Switching Image Source Key Use this key to switch the image sources in full image When split screen is activated this key does not have any function Resizing Split Screen Keys Use t...

Page 27: ...These functions are identical to the ones of the control panel You can operate all functions of the menu bar either using the mouse or the keyboard The most required functions have got global hotkeys...

Page 28: ...verse the mode True Colour will be selected again As another option you can control the colour modes using hotkeys When you click on the button with the right mouse key a context menu will be opened i...

Page 29: ...u click on the button with the right mouse key a context menu will be opened in which you can select a pre defined brightness If you wish to make finer brightness adjustments please use Key 5 at the c...

Page 30: ...he following hotkeys are available Hotkey function Default combination Zoom Plus Ctrl Alt Num Plus Zoom Minus Ctrl Alt Num Minus Colour Mode Ctrl Alt Num 1 Lines Curtains Ctrl Alt Num 4 Mirror Ctrl Al...

Page 31: ...ed Thus it does not matter if it is a user defined or the default combination You can always change the hotkey combination and adjust it according to your wishes Please select the appropriate hotkey f...

Page 32: ...description of the kind of disturbance Saftey Advice Before starting to operate the VISULEX device the user should read this manual The device may only be used in closed and dry rooms The ambient temp...

Page 33: ...e The device comply with the requirements of the European Union Medical Devices Directive as an active class I medical product intended to be used for the purpose of compensation for a handicap This p...

Page 34: ...roduct a minimum distance of 30 cm 1 ft shall be respected Do not expose the product to strong pressure and do not drop any objects on the product This might damage the product or lead to malfunctions...