the moment, all setting values on the display screen will flash 1 time to signal whole setting
procedure is confirmed and all setting values shown on the screen as they are set.
(k)
Situation which setting is interrupted:
At any mode, the program will leave setting procedure and give up setting when setting action is
inactive
beyond 3 minutes
.
*In case of FIRST TIME setting, the program will leave such mode setting and shown the status of
(a) which is MO-SU are shown and cursor under MO is blinking.
*If second time or further times setting, the program will
give up all settings have been done and
show the previous setting values
.
(l)
Set the manual “VALVE ON” :
Press button
Zone 1 On/Off
to activate compulsive watering of Zone 1 for the setting minutes. Or
press
Zone 2 On/Off
to activate compulsive watering of Zone 2 for the setting minutes. The digital
value will be count down and indicated automatically. Under such situation, the programmed
settings will be interrupted and timer will be instructed to watering immediately.
(m)
Set the manual “VALVE OFF” :
(n)
Under the status of “VALVE ON”, press button
Zone 1 On/Off
to stop watering instruction.
(o)
Low Battery :
Under the weekdays, the icon of battery will keep flashing. At the moment, the programmer will
lock the valve to be OFF situation.
You must replace a new battery immediately.
<Recommend you to use Alkaline battery>
C.
NOTES :
1. When set value of any mode, lasting press button
Zone 1 On/Off
to increase the value or press
Zone 2 On/Off
to decrease the value reading swiftly.
2. Title of “START” time and its value will not be shown if the week day is not attached by icon of
raindrop or such weekday is not programmed to water.
3. When “VALVE ON” is activated, “RUN TIME” will be blinking. Its value is shown and begins
to count down while watering is in progress.
4. The execution priority of watering program is discerned by the setting of watering days.
For example: If setting value of “START” time or “CYCLE TIME” is beyond current day and
next day is
programmed as non-watering date. The timer will no activate water operation and drop the
execution of “START” time or “CYCLE TIME” setting on next day.
5. Under the status of “Prog. OFF”, “START” time will not be shown on screen.
D.
SPECIAL REMARK :
1. Programmed watering schedule will be overridden by instruction of compulsive watering
(Manual water ON).
2. When programmed watering schedule is interrupted, unfinished cycle will be cancelled
automatically.
3. When programmed watering schedule is executed, any mode setting is unable to carry out at
same time.
4. When programmed “START” watering time for ZONE 1 and ZONE 2 at the same time, the
ZONE 1 valve will be open firstly, then open the ZONE 2 valve after 3 seconds.
5. When programmed watering schedule is executed and accomplished, the value of “START”
time will be renewed for next cycle automatically.
For example :
Watering one time a day (CYCLE TIME : 24 hrs)
If : TIME 6:00
START 7:00
RUN TIME 10min
MIST CYCLE 30%
CYCLE TIME 1DAY