background image

24 User’s Manual

5.2 U

SER

 A

CCESS

 C

ODES

Your system can support up to 95 User Access Codes. All codes
are given a User Number between 02 and 96 (Code 01 is the

System Master Code

).

User Access Codes can be programmed with various options
that will allow you to control the access to your system. Only the

System Master Code

 and codes with the 

Master

 feature can

program User Access Codes with their User Options and Area
Assignment.

4) Enter the numbers 

[0] 

and

 [1]

.

The keypad will emit a Confirmation Beep. The 

[

PRG

]

 Sym-

bol and the Numerical Symbol of the first number in the 
code will illuminate ([10] = zero). The Area Symbols and 

[

ACCESS

]

 Symbol will extinguish.

5) Enter a

 [

NEW

 

CODE

]

.

The Numerical Symbols for the next numbers in the code 
will illuminate one at a time as you enter the new code. 
When you have entered the maximum number of digits, the 
keypad will emit a Confirmation Beep.

6) Press the  button to exit.

KLEDEU03.fm  Page 24  Friday, May 4, 2001  11:25 AM

Summary of Contents for Digiplex DGP-620

Page 1: ...Digiplex LED Keypads User s Manual KLEDEU03 fm Page 1 Friday May 4 2001 11 25 AM...

Page 2: ...KLEDEU03 fm Page 0 Friday May 4 2001 11 25 AM...

Page 3: ...Display 8 3 0 ARMING 10 3 1 Exit Delay Timer 10 3 2 Regular Arming 10 3 3 Stay Arming 11 3 4 Instant Arming 12 3 5 Force Arming 13 3 6 One Touch Buttons 14 3 7 Keyswitch Arming 15 3 8 Auto Arming 16...

Page 4: ...7 3 Panic Alarms 33 7 4 Programming Chime Zones 34 7 5 Quick Function Buttons 36 8 0 FIRE AND BURGLAR ALARMS 37 8 1 Standard Fire Zone 37 8 2 Delayed Fire Zone 38 8 3 Fire Safety Tips 40 8 4 Minimizin...

Page 5: ...10 1 Zone Description 44 10 2 Special Buttons and Features 46 10 3 User Access Codes 48 KLEDEU03 fm Page 3 Friday May 4 2001 11 25 AM...

Page 6: ...l carefully and have your installer explain basic system operation 1 1 LEGEND Indicates a warning or an important note Indicates useful information or tip WORD NUMBER Indicates information that must b...

Page 7: ...LED Keypads 5 Figure 2 1 Basic Overview 2 1 AUDITORY FEEDBACK BEEP TONES When you enter information on the keypad the keypad will guide KLEDEU03 fm Page 5 Friday May 4 2001 11 25 AM...

Page 8: ...s status or when an operation is incorrectly entered the keypad emits a continuous beep BEEEEEEEEP 2 2 KEYPAD INDICATOR LIGHTS On all LED Keypads the state of the STATUS AC Lights and Action Symbols s...

Page 9: ...e 5 2 3 2 Confidential Mode The installer can program the keypads not to display the status of your system automatically by changing the LED keypad from Normal Mode to Confidential Mode In Confidentia...

Page 10: ...hereas another person may have access to all areas Access to the areas is determined by the User Access Code 2 5 AREA STATUS DISPLAY In Area Status Display you will be able to see the status of the in...

Page 11: ...any troubles are occurring The STAY Symbol if the area is Stay or Instant Armed The FORCE Symbol if the area is Force Armed The BYP Symbol if zones are bypassed The state of the Status Light How do I...

Page 12: ...to exit the protected area before the system is armed The Status Light will flash green while the time elapses The timer can be assigned different time limits and the keypad can be programmed to beep...

Page 13: ...at home without arming the motion detectors so you will be protected while you sleep Only User Access Codes with the Stay and Instant Arm option enabled can Stay Arm the system Also see section 3 8 on...

Page 14: ...alarm zones Therefore if any armed zone is breached the alarm will instantly be triggered Only User Access Codes with the Stay and Instant Arm option enabled will be able to Instant Arm How do I Stay...

Page 15: ...Force Arm option enabled can Force Arm the system Also see section 3 8 on page 16 Auto Arming for another everyday arming option This feature is commonly used when a motion detector is protecting an...

Page 16: ...the touch of a button you can view the Area Status Display see section 2 5 for a Partitioned System see section 2 4 Press and hold Your installer can also program your system to respond to How do I Fo...

Page 17: ...ur installer can add a keyswitch to arm and disarm your system The keyswitch can be programmed to Regular Stay Force or Instant Arm and Disarm a specific area The keyswitch will also be programmed by...

Page 18: ...timer 1 Enter your ACCESS CODE The keypad will emit a Confirmation Beep The ACCESS Symbol will flash 2 Press the button The keypad will emit a Confirmation Beep The PRG Sym bol and Area Symbol s will...

Page 19: ...on This will enable you to program the system to bypass certain zones when you arm the protected area When a zone is bypassed it will remain unarmed once the system is armed This option may be useful...

Page 20: ...your ACCESS CODE The keypad will emit a Confirmation Beep The ACCESS Symbol will flash 2 Press the button The PRG Symbol will illuminate and the BYP Symbol will flash 3 Enter the two digit number s o...

Page 21: ...How do I activate Bypass Recall 1 Enter your ACCESS CODE The keypad will emit a Confirmation Beep The ACCESS Symbol will flash 2 Press the button The keypad will emit a Confirmation Beep The PRG Sym...

Page 22: ...the installer will program designated entry points such as the front door or the garage door with an entry delay This delay will allow you enough time to enter your code to disarm the system before t...

Page 23: ...ntry The keypad will beep to acknowledge the entry the Status Light will turn red and the Entry Delay Timer will begin the countdown 2 Enter your ACCESS CODE 3 Press the button If you have access to m...

Page 24: ...e that area is armed 5 0 ACCESS CODES Access Codes are codes that will allow you and others to access the system These codes can be programmed to permit access to all or some features and areas The in...

Page 25: ...e features as well as the ability to add modify or delete any User Access Codes We suggest that you change this code to prevent others from accessing and changing your options without authorization Ho...

Page 26: ...Access Codes with their User Options and Area Assignment 4 Enter the numbers 0 and 1 The keypad will emit a Confirmation Beep The PRG Sym bol and the Numerical Symbol of the first number in the code w...

Page 27: ...gram The ACCESS Symbol will flash for an unused code If the code is used PRG Symbol and first number of the code will illuminate The ACCESS Symbol and the Area Symbols will extinguish 5 Enter a User C...

Page 28: ...10 represents zero 5 3 USER OPTIONS Options on the User Access Codes that activate access to features The User Code Option or Area is considered ON when the corresponding Numerical Symbol is illumina...

Page 29: ...on 4 Bypass Feature When option 4 is ON the Bypass feature is enabled This feature allows you to deactivate zones Option 5 Arm Only Feature When option 5 is ON the Arm Only feature is enabled The user...

Page 30: ...to four distinct protected areas Programming access to a specific area or areas is called Area Assignment User Access Codes are only able to perform actions arming disarming etc in the area s the code...

Page 31: ...TRBL Symbol will illuminate Most of the trouble conditions will be programmed by your installer to be reported directly to your Security Company if connected The keypad will only display troubles tha...

Page 32: ...e turned off during a power failure If this Trouble occurs when your establishment is not experiencing a power failure call your Security Company for repairs Trouble 2 Battery Trouble This means the b...

Page 33: ...the device will flash to indicate this trouble 6 0 4 Group 7 Zone Fault A smoke detector is experiencing a wiring problem needs to be cleaned or a wireless device is no longer communicating with its r...

Page 34: ...Numerical Symbol are illuminated 2 Enter the hour and minutes according to a 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 The default time will be illuminated one number at a time as you enter...

Page 35: ...ou press the and buttons at the same time and hold them for two seconds the system will generate an alarm The alarm can be programmed to be either silent or audible according to your preference Auxili...

Page 36: ...nly when opened between certain hours These zones are referred to as Chime Zones Each keypad must be Chime programmed separately Your installer can program your Chimed zones to also beep upon closure...

Page 37: ...lluminate If you re enter the number of an illuminated Numerical Symbol the corresponding zone will unchime and the Numerical Symbol will extinguish 5 Press the button to exit How do I program all the...

Page 38: ...presents the first number of the previously set time 10 Symbol zero When the A2 and A3 Symbols flash no time is set 4 Enter the time you want all Chimed zones to start beeping when they open according...

Page 39: ...ecurity Company How do I access the Quick Function Buttons 1 Enter your SYSTEM MASTER CODE or ACCESS CODE with Master feature 2 Press the button 3 Press one of the following for the system to button s...

Page 40: ...is a Delayed Fire Zone there is an automatic delay before the system contacts the Security Company see Figure 8 1 This will prevent unnecessary reporting of false alarms If you are unable to cancel t...

Page 41: ...LED Keypads 39 Figure 8 1 Delayed Fire Zone KLEDEU03 fm Page 39 Friday May 4 2001 11 25 AM...

Page 42: ...ide 3 Practice the escape plan frequently 4 Plan two ways to escape from every room if possible 5 Practice feeling the way out with eyes closed 6 Remind everyone never to stand up during a fire always...

Page 43: ...ant fire deterrents 3 Maintain your heating system Heating is the second leading cause of residential fires However heating fires are a larger problem in single family homes than in apartments Unlike...

Page 44: ...R ALARM TESTING Two people are needed to complete this test One person will watch the keypad while the other person walks around and opens the zones i e open the doors and windows that are protected w...

Page 45: ...ded that your installer change the battery every three years 9 4 SYSTEM TEST Speak to your installer before conducting a system test since the system must be programmed to respond to the test instruct...

Page 46: ...___________________________________________ Area 3 ____________________________________________ Area 4 ____________________________________________ 3 Press the button The system will test all its conn...

Page 47: ...l l l l 21 l l l l 05 l l l l 22 l l l l 06 l l l l 23 l l l l 07 l l l l 24 l l l l 08 l l l l 25 l l l l 09 l l l l 26 l l l l 10 l l l l 27 l l l l 11 l l l l 28 l l l l 12 l l l l 29 l l l l 13 l...

Page 48: ...l 39 l l l l 46 l l l l 40 l l l l 47 l l l l 41 l l l l 48 l l l l Entry Delay Exit Delay Area 1 is _____ seconds Area 1 is _____ seconds Area 2 is _____ seconds Area 2 is _____ seconds Area 3 is __...

Page 49: ...tay Arming l Bypass Programming l Force Arming l Instant Arming l Regular Arming l Backlight l Disarm Stay or Instant Arming l Emergency or__________ l Silent l Audible l Auxiliary or____________ l Si...

Page 50: ...R ACCESS CODES User Name Area s Card s Serial User Name Area s Card s Serial 01 18 02 19 03 20 04 21 05 22 06 23 07 24 08 25 09 26 10 27 11 28 12 29 13 30 14 31 15 32 16 33 17 34 KLEDEU03 fm Page 48 F...

Page 51: ...4 36 55 37 56 38 57 39 58 40 59 41 60 42 61 43 62 44 63 45 64 46 65 47 66 48 67 49 68 50 69 51 70 52 71 53 72 User Name Area s Card s Serial User Name Area s Card s Serial KLEDEU03 fm Page 49 Friday M...

Page 52: ...50 User s Manual 73 92 74 93 75 94 76 95 77 96 78 79 80 81 82 83 84 85 86 87 88 89 90 91 User Name Area s Card s Serial User Name Area s Card s Serial KLEDEU03 fm Page 50 Friday May 4 2001 11 25 AM...

Page 53: ...KLEDEU03 fm Page 51 Friday May 4 2001 11 25 AM...

Page 54: ...KLEDEU03 fm Page 52 Friday May 4 2001 11 25 AM...

Reviews: