background image

5

4

Life Support Policy

As a general policy, Para Systems does not recommend the use of any of our
products in life support applications where failure or malfunction of the product
can be reasonably expected to cause failure of the life support device or to
significantly affect its safety or effectiveness.  We do not recommend the use of
any of our products in direct patient care.  We will not knowingly sell our prod-
ucts for use in such applications unless it receives in writing assurances satis-
factory to us that (a) the risks of injury or damage have been minimized,  (b) the
customer assumes all such risks, and (c) our liability is adequately protected
under the circumstances.

Examples of devices considered to be life support devices are neonatal oxygen
analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other
purposes), auto transfusion devices, blood pumps, defibrillators, arrhythmia
detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis
systems, neonatal ventilator incubators, ventilators for both adults and infants,
anesthesia ventilators, and infusion pumps as well as any other devices desig-
nated as “critical” by the United States FDA.

After removing your UPS from its carton, it should be inspected for damage that
may have occurred in shipping.  Immediately notify the carrier and place of
purchase if any damage is found.  Warranty claims for damage caused by the
carrier will not be honored.  The packing materials that your UPS was shipped
in are carefully designed to minimize any shipping damage.  In the unlikely
case that the UPS needs to be returned to the manufacturer, please use the
original packing material.  Since the manufacturer is not responsible for ship-
ping damage incurred when the system is returned, the original packing mate-
rial is inexpensive insurance.  

PLEASE SAVE THE PACKING MATERIALS!

Receiving Inspection

NOTICE:   

This equipment has been tested and found to comply with the limits

for a Class B computing device in accordance with the specifications in Sub-
part J of Part 15 of FCC Rules and the Class B limits for radio noise emissions
from digital apparatus set out in the Radio Interference of the Canadian Depart-
ment of Communications.  These limits are designed to provide reasonable
protection against such interference in a residential installation.  This equip-
ment generates and uses radio frequency and if not installed and used properly,
that is, in strict accordance with the manufacturer's instructions, this equip-
ment may cause interference to radio and television reception.  If this equip-
ment does cause interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

Re-orient the receiving antenna.

Relocate the computer with respect to the receiver.

Move the computer away from the receiver.

Plug the computer into a different outlet so that the computer and receiver
are on different branch circuits.

Shielded communications interface cables must be used with this product.

WARNING: 

 

Changes or modifications to this unit not expressly ap-

proved by the party responsible for compliance could void the user's
authority to operate the equipment.

NOTE:

  These UPSs are shipped with the batteries disconnected.  The batter-

ies must be connected before putting these UPSs into service.  Refer to Sec-
tion 3 "Installation" for connecting the batteries.

CAUTION!

  This UPS series is 

ONLY

 intended to be installed in an

indoor temperature controlled environment that is free of conductive
contaminants.  This UPS series is not intended for use in a computer
room as defined in the Standard for the Protection of Electronic
Computer/Data Processing Equipment ANSI/NFPA 75.

CAUTION!

  The Maximum ambient operating temperature for this

UPS series is 40°C (“0 ~ 40°C” for Ambient Operation).

ON / OFF / TEST BUTTON:  

Press and release the On/Off/Test But-

ton after one beep to turn the UPS on and supply power to the load.
The load is immediately powered while the UPS runs a five-second
self test.  Press and release the On/Off/Test Button after one beep to
turn the UPS off.  The UPS will continue to charge the batteries when-
ever it is plugged into a wall outlet and there is acceptable AC voltage
present.  To perform a ten-second battery test:  With the UPS in the
AC mode, press and hold the On/Off/Test Button until the alarm sounds
four beeps, and then release.  During the test, the UPS will switch to
the Battery mode, the On-Battery icon will illuminate and the alarm
will sound.

Summary of Contents for E1000RT2U

Page 1: ...er s Manual Enterprise Plus LCD RT UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000434...

Page 2: ...s and Indicators 6 3 Installation 9 4 Operation 15 5 Troubleshooting 19 6 Replacing the Battery 20 7 Obtaining Service 23 8 Specifications 24 9 Configurable Parameters Settings 26 10 Limited Product W...

Page 3: ...ease read this manual before installing your Enterprise Plus Series UPS models E750RT2U E1000RT2U E1500RT2U E2000RT2U E3000RT2U as it provides important information that should be followed during inst...

Page 4: ...part ment of Communications These limits are designed to provide reasonable protection against such interference in a residential installation This equip ment generates and uses radio frequency and if...

Page 5: ...Load Level Bar Graph will be illuminated and the UPS will sound a constant alarm to indicate that there is an Overload condi tion The Battery Capacity Bar Graph operates as follows LED 1 When the bat...

Page 6: ...wired into two segments to support the Load Shedding Function Labeled Load 1 Load 2 The locking and Always On receptacles La beled Load 3 do not support the Load Shedding Function NOTE The locking re...

Page 7: ...andard 19 46 5cm rack installed on the UPS The mounting brackets to fit a 23 59 2cm rack and Rail Kits for 4 post racks and cabinets are also available The screws for mounting the UPS to the rack are...

Page 8: ...e UPS On the backside of the front panel push the LCD panel out wards the panel will pop out Position the LCD panel so that it reads in the up right position Re install the front panel on the UPS 8 Th...

Page 9: ...rly without this connection For USB port see Note on page 17 CONNECTING THE UPS TO AN AC SOURCE Plug the UPS into a two pole three wire groundedAC wall outlet TheAC wall outlet shall be near the UPS a...

Page 10: ...tery s capability to provide an acceptable amount of runtime If the UPS fails a self test one of the icons will remain illuminated indicating the type of problem NOTE The UPS will automatically perfor...

Page 11: ...ps after UPS restarts reduce the load on the UPS UPS operates in battery mode only even though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cabl...

Page 12: ...frequent short duration discharges have a negative impact on battery life NOTE If there is a power interruption while replacing the hot swappable batteries with the UPS on the load will not be backed...

Page 13: ...and address B Where and when the unit was purchased C All of the model information about your UPS D Any information on the failure including LEDs that may be illuminated E Adescription of the protect...

Page 14: ...ull load discharge BM0031 Battery Type Sealed Non Spillable Maintenance Free Value Regulated LeadAcid System Voltage Runtime Full Load minutes Runtime Half Load minutes 13 11 17 5 4 8 SURGE PROTECTION...

Page 15: ...oducts that are depot repaired or replaced pursuant to this warranty shall be warranted for the unexpired portion of the warranty applying to the original product This warranty applies only to the ori...

Page 16: ...tible Power Supplies UPS Model No E750RT2U Y E1000RT2U Y E1500RT2U Y E2000RT2U Y E3000RT2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texa...