background image

25

24

Default: 120VAC, User selectable: 125VAC

750VA
600W

1500VA
1200W

1000VA
800W

Protection

Waveform Type

Over-Current, Short-Circuit Protected and Latching Shutdown

Sine Wave

Frequency

50/60Hz, +/-0.1Hz (unless synchronized to utility)

Nominal Voltage

Maximum Power Capacity

4-6 ms Typical

>93% (Full Load)

Resettable Circuit Breaker

50 or 60 Hz, +/-6Hz, autosensing

0 - 165VAC

80 - 164VAC

120VAC: 101 - 136VAC

Transfer Time

Efficiency (Line Mode)

Input Protection

Frequency Limits

Voltage Range

Acceptable Input voltage

E1500RT2U

E1000RT2U

E750RT2U

Model Number

SYSTEM SPECIFICATIONS

Voltage Range

Topology

Line-Interactive, Sine Wave

OUTPUT NON-BATTERY OPERATION

INPUT

Number of Phase

Single (1

 

2W +G)

Nominal Voltage

120VAC

Low Voltage Transfer Point

80V resets to Utility Power at 85V or higher

High Voltage Transfer Point

164V resets to Utility Power at 159V or lower

Voltage Regulation

120VAC: -15.8% - +11.7%

Frequency Range

60Hz: 54 - 66Hz or 50Hz: 44 - 56Hz

OUTPUT BATTERY OPERATION

Voltage Regulation

N/-5% (until Low Battery Warning)

Voltage T.H.D.

<5% (Linear Load)

+/-10% @ 100% Load change in 30 ms

Dynamic Response

Slew Rate

<1Hz / second

Overload Capacity

110% for 20-seconds
125% for 10-seconds
150% Shutdown Immediately

E2000RT2U E3000RT2U

2000VA
1760W

3000VA
2560W

BATTERY SYSTEM

Typical Recharge Time

Typical Battery Life

Battery Module

3-5 years, depending on discharge cycles and ambient temp

BM0029

BM0030

8-hours to 90% after full load discharge

BM0031

Battery Type

Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid

System Voltage

Runtime: Full Load (minutes)

Runtime: Half Load (minutes)

13

11

17

5

4

8

SURGE PROTECTION AND FILTERING

Audible Noise at 1 m (3 ft.)

10/100 Base-T surge protection

let-through (as a percentage of

an a/-2 kV 1.2/50 us, 500

a 8/20 uS test)

Telephone line surge protection

let-through (as a percentage of

an a/-2 kV 1.2/50 us,

500a 8/20 uS test)

Noise Filter

Surge voltage let-through (as a

percentage of an applied ANSI

C62.41 Cat. A +/-2 kV)

Surge Response Time

Surge Current Capability

Surge Energy Rating

1000 J

0 ns (instantaneous) normal mode; <5 ns common mode

<5%

normal and common mode EMI/RFI suppression

<45 dBA

<1%

<5%

6500 Amps total

ENVIRONMENTAL

Operating Temperature (max)

Operating/Storage Humidity

Operating Elevation

0 to 40

°

C (+32 to +104

°

F)

95% Non-Condensing

0 to 3,000m (0 to +10,000 ft)

PHYSICAL

Weight - Net

Size - Net   L X W X H
(rackmount brackets installed)

Size - Shipping
L X W X H

Weight - Shipping

17.4 x 19.0 x 3.5"
442 x 482.6 x 89 mm

23.6 x 21.7 x 9.1"
600 x 551 x 230 mm

REGULATORY COMPLIANCE

Safety and Approvals

EMC Verification

cUL (UL1778 4th Edition & CSA 22.2 no. 107.3-05)

FCC Class B, CE certified

Storage Elevation

0 to 15,000m (0 to +50,000 ft)

Storage Temperature

-15 to +45

°

C (+5 to +113

°

F)

36VDC

72VDC

BM0029

BM0032

8

3

15

5

<60 dBA

24.0 x 19.0 x 3.5"
610 x 482.6 x 89 mm

39.4 x 23.6 x 9.1"
1000 x 600 x 230 mm

78.0 lbs
35.4 Kgs

97.0 lbs
44.0 Kgs

72.1 lbs
32.7 Kgs

91.5 lbs
41.5 Kgs

44.1 lbs
20.0 Kgs

53.8 lbs
24.4 Kgs

41.2 lbs
18.7 Kgs

51.0 lbs
23.1 Kgs

43.7 lbs
19.8 Kgs

53.6 lbs
24.3 Kgs

Summary of Contents for E750RT2U

Page 1: ...er s Manual Enterprise Plus LCD RT UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000434...

Page 2: ...s and Indicators 6 3 Installation 9 4 Operation 15 5 Troubleshooting 19 6 Replacing the Battery 20 7 Obtaining Service 23 8 Specifications 24 9 Configurable Parameters Settings 26 10 Limited Product W...

Page 3: ...ease read this manual before installing your Enterprise Plus Series UPS models E750RT2U E1000RT2U E1500RT2U E2000RT2U E3000RT2U as it provides important information that should be followed during inst...

Page 4: ...part ment of Communications These limits are designed to provide reasonable protection against such interference in a residential installation This equip ment generates and uses radio frequency and if...

Page 5: ...Load Level Bar Graph will be illuminated and the UPS will sound a constant alarm to indicate that there is an Overload condi tion The Battery Capacity Bar Graph operates as follows LED 1 When the bat...

Page 6: ...wired into two segments to support the Load Shedding Function Labeled Load 1 Load 2 The locking and Always On receptacles La beled Load 3 do not support the Load Shedding Function NOTE The locking re...

Page 7: ...andard 19 46 5cm rack installed on the UPS The mounting brackets to fit a 23 59 2cm rack and Rail Kits for 4 post racks and cabinets are also available The screws for mounting the UPS to the rack are...

Page 8: ...e UPS On the backside of the front panel push the LCD panel out wards the panel will pop out Position the LCD panel so that it reads in the up right position Re install the front panel on the UPS 8 Th...

Page 9: ...rly without this connection For USB port see Note on page 17 CONNECTING THE UPS TO AN AC SOURCE Plug the UPS into a two pole three wire groundedAC wall outlet TheAC wall outlet shall be near the UPS a...

Page 10: ...tery s capability to provide an acceptable amount of runtime If the UPS fails a self test one of the icons will remain illuminated indicating the type of problem NOTE The UPS will automatically perfor...

Page 11: ...ps after UPS restarts reduce the load on the UPS UPS operates in battery mode only even though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cabl...

Page 12: ...frequent short duration discharges have a negative impact on battery life NOTE If there is a power interruption while replacing the hot swappable batteries with the UPS on the load will not be backed...

Page 13: ...and address B Where and when the unit was purchased C All of the model information about your UPS D Any information on the failure including LEDs that may be illuminated E Adescription of the protect...

Page 14: ...ull load discharge BM0031 Battery Type Sealed Non Spillable Maintenance Free Value Regulated LeadAcid System Voltage Runtime Full Load minutes Runtime Half Load minutes 13 11 17 5 4 8 SURGE PROTECTION...

Page 15: ...oducts that are depot repaired or replaced pursuant to this warranty shall be warranted for the unexpired portion of the warranty applying to the original product This warranty applies only to the ori...

Page 16: ...tible Power Supplies UPS Model No E750RT2U Y E1000RT2U Y E1500RT2U Y E2000RT2U Y E3000RT2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texa...

Reviews: