BATTERY SYSTEM

Typical Recharge Time

Typical Battery Life

Battery: Quantity/Rating

3-5 years, depending on discharge cycles and ambient temp

4-12V7.2Ah

8-hours from total discharge

4-12V8.5Ah

Battery Type

Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid

System Voltage

48VDC

48VDC

Runtime: Full Load (minutes)

Runtime: Half Load (minutes)

13

13

4

4

SURGE PROTECTION AND FILTERING

Audible Noise at 1 m (3 ft.)

10/100 Base-T surge protec-

tion let-through (as a percent-

age of an a/-6 kV 1.2/

50 us, 500 a 8/20 uS test)

Telephone line surge protec-

tion let-through (as a percent-

age of an a/-6 kV 1.2/

50 us, 500a 8/20 uS test)

Noise Filter

Surge voltage let-through (as

a percentage of an applied

ANSI C62.41 Cat. A +/-6 kV)

Surge Response Time

Surge Current Capability

Surge Energy Rating

800 J (600 J)

0 ns (instantaneous) normal mode; <5 ns common mode

<5%

normal and common mode EMI/RFI suppression

<45 dBA

<1%

<5%

6500 Amps total

ENVIRONMENTAL

Operating Temperature (max)

Operating/Storage Humidity

Operating Elevation

0 to 40

°

C (+32 to +104

°

F)

95% Non-Condensing

0 to 3,000m (0 to +10,000 ft)

PHYSICAL

Weight - Net

Size - Net
D X W X H

Size - Shipping
D X W X H

Weight - Shipping

43.1 lbs
19.6 Kgs

67.7 lbs
30.7 Kgs

13.1 x 17.3 x 3.5"
335 x 440 x 89 mm

23.6 x 20.0 x 9.0"
600 x 508 x 230 mm

52.0 lbs
23.3 Kgs

80.0 lbs
35.9 Kgs

REGULATORY COMPLIANCE

Safety and Approvals

EMC Verification

UL1778, cUL (CSA 22.2 no. 107.1)

FCC, CE certified

Storage Elevation

0 to 15,000m (0 to +50,000 ft)

Storage Temperature

-15 to +45

°

C (+5 to +113

°

F)

24VDC

72VDC

2-12V8.5Ah

6-12V8.5Ah

15

5

13

4

<60 dBA

24.0 x 17.3 x 3.5"
610 x 440 x 89 mm

39.4 x 23.6 x 9.0"
1000 x 600 x 230 mm

46.2 lbs
21.0 Kgs

55.0 lbs
24.7 Kgs

40.0 lbs
17.9 Kgs

29.0 lbs
13.2 Kgs

17.0 x 17.3 x 3.5"
432 x 440 x 89 mm

23.6 x 20.0 x 9.0"
600 x 508 x 230 mm

(These items may require optional software or hardware)

Function

Factory
Default

Description

User Choices

Set
inverter
output
voltage

Shut-

down

Type

Set

audible

alarm

state

Enable/

Disable

auto

restart

Battery

life in

days

Battery

install

date

UPS ID

Endeavor
Series

Date of

manufacture

1826

Enabled

Enabled

Entire UPS

120VAC

(208VAC)

Up to 64 charac-
ters to define
the UPS

Date of battery

replacement -

month/day/year

XX/XX/XXXX

Up to 5

characters

Enable

or

Disable

Enabled, at

low battery,

disabled

Entire UPS  or

UPS output

110, 115,  120VAC
(208, 230, 240VAC)

At first battery replacement, reset
to reflect actual number of days
experience in your environment or
leave factory default

Enter the current date when replac-
ing batteries

Use this function to uniquely

identify the UPS in your network

configuration

Changes output voltage for bat-
tery mode operation

Enabled - the UPS will emit a

short beep when in the battery

mode.  At Low Battery  the UPS

will emit two beeps from low

battery warning until shutdown.

Disabled - Use only when software

is controlling the UPS or to

silence the alarm

When  enabled, the UPS will

automatically restart from a low

battery shutdown when normal AC

returns

Enable/

Disable

REPO

Disabled

Enable

or

Disable

Enabled - the UPS will be
completely powered off and  re-
main off until the UPS is reset

Entire UPS - Turns off the entire
UPS.
UPS Output -  Turns off the UPS's
output receptacles only.

Summary of Contents for ED1000RM2U

Page 1: ...User s Manual Endeavor Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000274 On Line UPS...

Page 2: ...d Indicators 6 3 Installation 9 4 Operation 15 5 Troubleshooting 18 6 Replacing the Battery 19 7 Obtaining Service 22 8 Specifications 23 9 Configurable Parameters Settings 25 10 Limited Product Warra...

Page 3: ...read this manual before installing your Endeavor On Line Series UPS models ED1000RM2U ED1000RMT2U ED1500RM2U ED1500RMT2U ED2000RM2U ED2000RMT2U ED3000RM2U ED3000RMT2U as it provides important informa...

Page 4: ...in are carefully designed to minimize any shipping damage In the unlikely case that the UPS needs to be returned to the manufacturer please use the original packing material Since the manufacturer is...

Page 5: ...ady state when the UPS reaches a low battery condition The BATT LOW LED is extinguished when the UPS is in the On Line mode and when the battery is not in a low battery condition The REPLACE BATT red...

Page 6: ...Receptacles ED1000RM2U NEMA 5 15P Model ED2000RM2U ED3000RM2U ED1500RM2U Input Power Plug All power cords are 10ft ED1000RMT2U ED1500RMT2U NEMA 5 15P NEMA 5 20P NEMA L5 30P NEMA 6 15P NEMA 6 15P 6 NEM...

Page 7: ...ARN ING Use two or more people when installing the UPS Use CAUTION the UPS is extremely heavy Do not move the rack after the units have been in stalled The rack maybe unstable due to the weight distri...

Page 8: ...lows the user to mount the UPS on the wall There is a wallmount bracket kit available for the UPS The kit includes two wall mounting brackets ten retaining screws and the wallmount template WARNING Us...

Page 9: ...Battery mode short pin4 to pin5 for approximately 0 5 seconds to shutdown the UPS The UPS must be turned off and then back on again to restart the UPS NOTE Connecting to the REPO port is optional The...

Page 10: ...will illuminate and the UPS will sound a constant alarm This alarm will remain on until the excess load is removed or the UPS s self protec tion circuit shuts the UPS down COMMUNICATIONS PORTS RS232 a...

Page 11: ...le Power Supply contains potentially hazardous voltages Do not attempt to disassemble the UPS beyond the battery replacement procedure This UPS contains no user serviceable parts Repairs and Battery r...

Page 12: ...12 LC R129 HR 1234W F2 8 Remove the two retaining screws for the battery retaining bracket FIG 3 9 Remove the battery retaining bracket FIG 3 10 Disconnect the Battery connectors red and black FIG 4...

Page 13: ...r a copy of your original sales receipt and a brief description of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outside...

Page 14: ...e 15 to 45 C 5 to 113 F 24VDC 72VDC 2 12V8 5Ah 6 12V8 5Ah 15 5 13 4 60 dBA 24 0x17 3x3 5 610x440x89mm 39 4x23 6x9 0 1000x600x230mm 46 2 lbs 21 0 Kgs 55 0 lbs 24 7 Kgs 40 0 lbs 17 9 Kgs 29 0 lbs 13 2 K...

Page 15: ...r after delivery in regard to use or appli cation of Para Systems s equipment is furnished without charge and on the basis that it represents Para Systems s best judgment under the circumstances but i...

Page 16: ...ay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No ED1000RM2U Y ED1500RM2U Y ED2000RM2U Y ED3000RM2U Y I hereby declare that the equipment specified abov...

Page 17: ...30 English Notes...

Reviews: