9 Obtaining 

Service 

 
9.1.1 

Use the troubleshooting section to eliminate obvious causes. 

9.1.2 

Verify there are no circuit breakers tripped. A tripped circuit breaker is the 

most common problem. Call your dealer for assistance. If you cannot reach 
your dealer, or if they cannot resolve the problem call or fax MINUTEMAN 
Technical Support at the following numbers; Voice phone (972) 446-7363, 
FAX line (972) 446-9011 or visit our Web site at www.minutemanups.com 
the "Discussion Board". Please have the following information available 
BEFORE calling the Technical Support Department. 

a.  Your name and address. 
b.  Where and when the unit was purchased. 
c.  All of the model information about your unit. 
d.  Any information on the failure. 
e.  A technician will ask you for the above information and, if possible, help 

solve your problem over the phone. In the event that the unit requires 
factory service, the technician will issue you a Return Material 
Authorization Number (RMA #). 

f.  If the unit is under warranty, the repairs will be done at no charge. If not, 

there will be a charge for repair. 

9.1.3 

Pack the unit in its original packaging. If the original packaging is no longer 

available, ask the Technical Support Technician about obtaining a new set. 
It is important to pack the unit properly in order to avoid damage in transit. 
Never use Styrofoam beads for a packing material. 

a.  Include a letter with your name, address, daytime phone number, RMA 

number, a copy of your original sales receipt, and a brief description of 
the problem. 

b.  Mark the RMA # on the outside of all packages. The factory cannot 

accept any package without the RMA # marked on the outside. 

9.1.4 

Return the unit by insured, prepaid carrier to: 

 
 

Para Systems Inc. 

MINUTEMAN UPS 

1455 LeMay Drive 

Carrollton, TX 75007 

ATTN: RMA #   

 

 
 
 

 

41

10 Limited Product Warranty 

 

Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied 
and operated within specified conditions, against faulty materials or workmanship 
for a period of three years from the date of purchase. For equipment sites within the 
United States and Canada, this warranty covers repair or replacement of defective 
equipment at the discretion of Para Systems. Repair will be from the nearest 
authorized service center. Replacement parts and warranty labor will be borne by 
Para Systems. For equipment located outside of the United States and Canada, 
Para Systems only covers faulty parts. Para Systems products repaired or replaced 
pursuant to this warranty shall be warranted for the un-expired portion of the 
warranty applying to the original product. This warranty applies only to the original 
purchaser who must have properly registered the product within 10 days of 
purchase. 
 
The warranty shall be void if (a) the equipment is damaged by the customer, is 
improperly used, is subjected to an adverse operating environment, or is operated 
outside the limits of its electrical specifications; (b) the equipment is repaired or 
modified by anyone other than Para Systems or Para Systems-approved personnel; 
or (c) has been used in a manner contrary to the product’s User's Manual or other 
written instructions. 
 
Any technical advice furnished before or after delivery in regard to use or 
application of Para Systems’ equipment is furnished without charge and on the 
basis that it represents Para Systems’ best judgment under the circumstances, but 
it is used at the recipient’s sole risk. 
 
Except as provided herein, Para Systems makes no warranties, expressed or 
implied, including warranties of merchantability and fitness for a particular purpose. 
Some states do not permit limitation of implied warranties; therefore, the aforesaid 
limitation(s) may not apply to the purchaser. 

 

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE 
LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR 
CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, 
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Para 
Systems is not liable for any costs, such as lost profits or revenue, loss of 
equipment, loss of use of equipment, loss of software, loss of data, cost of 
substitutes, claims by third parties, or otherwise. The sole and exclusive remedy for 
breach of any warranty, expressed or implied, concerning Para Systems’ products 
and the only obligation of Para Systems hereunder, shall be the repair or 
replacement of defective equipment, components, or parts; or, at Para Systems’ 
option, refund of the purchase price or substitution with an equivalent replacement 
product. This warranty gives you specific legal rights and you may have other rights, 
which vary from state to state. 

 

Summary of Contents for Minuteman ED10000T

Page 1: ...Inc 1455 LeMay Drive Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000356 R3 ED10000T ED10200T Parallel Redundant ON LINE SERIES U...

Page 2: ...Storage instruction 12 3 4 Installation of the Castor Covers 13 3 5 Wiring the Input and Output Connections 14 3 6 Operation and Setup Instructions 19 4 Communication Port EPO Port and Option Cards 30...

Page 3: ...tteries 1 1 12 CAUTION A disconnect switch must be provided by the user for the AC output circuit when the UPS s output is hardwired To reduce the risk of fire connect only to a circuit provided with...

Page 4: ...the UPS for remote control and monitoring 2 2 4 These UPS systems can be used in a Parallel Redundant application To operate these UPS systems in the Parallel Redundant mode requires the Parallel Redu...

Page 5: ...2 Er06 Output Short Circuit 33 Er08 DC Bus high voltage level abnormal 34 Er09 DC Bus low voltage level abnormal 35 Er10 Inverter Over current 36 Er11 UPS Overheated 37 Er12 Inverter Overload 38 Er13...

Page 6: ...9 2 4 Controls and Indicators 2 4 1 UPS Control panel A LCD Display B N 1 green LED illuminates when the UPS is operating in the Parallel Redundant mode C Bypass green LED illuminates when the bypass...

Page 7: ...d by a qualified person If the package is deemed to be not usable immediately contact the freight carrier and the place of purchase USE CAUTION This UPS system is extremely heavy Always use the approp...

Page 8: ...000m 0 to 50 000 ft 3 3 Storage Instruction For extended storage with moderate climates the batteries should be charged for 12 hours every 3 months Repeat this procedure every 2 months under high temp...

Page 9: ...to the terminal blocks 3 5 1 1 1 OUTPUT connections for ED10000T Hardwired only Configurations 1 7 are for Hardwiring the output of ED10000T A Qualified Electrical Contractor must perform the hardwir...

Page 10: ...KVA max load per circuit and one 208VAC 10KVA circuit Total combined output load not to exceed 10KVA 1 Connect a jumper wire from L22 to N21 2 Circuit1 120VAC L22 Line N22 Neutral G2 Ground 3 Circuit2...

Page 11: ...to terminal G2 A Qualified Electrical Contractor must perform the hardwiring The outputs must be connected to an over current protection device circuit breaker of 50 amperes in accordance with the Nat...

Page 12: ...may be used immediately but the On Battery runtime maybe less than normally expected NOTE If the UPS is going to be out of service or stored for a prolonged period of time the batteries must be recha...

Page 13: ...ypass Input Drawing J Frequency from Utility Input Drawing K Frequency from Bypass Input Drawing L UPS Output Voltage Drawing M UPS Output Frequency Drawing N UPS Output Load Drawing O UPS Battery Vol...

Page 14: ...eck the UPS settings Drawing Q1 Buzzer audible alarm Drawing R1 Self test Drawing S1 Bypass Voltage Window Drawing T Output Frequency Synchronization Window Drawing U Inverter Output Voltage Drawing V...

Page 15: ...econds and then release the audible alarm will sound 2 beeps the LCD display screen shows as drawing Q1 then the UPS is under setting mode 3 6 5 2 Except for the Buzzer as drawing Q1 Q2 and the Self t...

Page 16: ...r on the rear panel of the Battery Pack 3 6 7 4 The UPS is OFF 3 6 7 5 To completely de energize the UPS disconnect the battery cable from the rear panel of the UPS Turn Off the utility circuit breake...

Page 17: ...on Wait for approximately 1 minute until the fans turn off then turn the input circuit breaker to the On position The UPS will be in the Bypass mode Press the On switch on the front panel for 2 beeps...

Page 18: ...er of the UPS The UPS should be unlocked but the original problem may not be resolved Call for Service 33 7 Replacing the Batteries QUALIFIED SERVICE PERSONNEL ONLY Please read all of the WARNINGS and...

Page 19: ...ining screws for the side panels on the rear panel of the UPS 7 1 9 Slide the side panels towards the rear of the UPS and lift up to remove the side panels and set aside FIG 2 FIG 1 FIG 2 35 7 1 10 Lo...

Page 20: ...37 7 1 32 Back to the right hand side of the UPS FIG 3 remove the piece of electrical tape from the end of battery positive Red wire Observer polarity Reconnect the battery positive Red wire NOTE Some...

Page 21: ...oltage let through as a percentage of an applied ANSI C62 41 Cat A 6KV 5 Noise Filter Normal and common mode EMI RFI suppression Audible Noise at 1 m 3 ft 50dB 160 280VAC at loads 50 of the rated capa...

Page 22: ...m the nearest authorized service center Replacement parts and warranty labor will be borne by Para Systems For equipment located outside of the United States and Canada Para Systems only covers faulty...

Page 23: ...Name Para Systems Inc MINUTEMAN UPS Manufacturer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No ED10000T ED10200T Year of Manufact...

Reviews: