1  Important Safety Instruction 

 

1.1. 

An Important Notice 

 
1.1.1 

To ensure safety in all applications where a UPS system is hardwired to 

the electrical supply the UPS must be installed by a Qualified Electrical 
Contractor. 

 
1.1.2 

The UPS has its own internal energy source (battery). If the UPS is 

switched on when there is no AC power is available, there could be voltage 
at the output terminals. 

 
1.1.3 

Servicing of the UPS system must be performed by 

Qualified Service 

Personnel ONLY.

    MINUTEMAN accepts no liabilities and is not limited to: 

injury to the Service Personnel, or damages to; the UPS system, or the 
connected equipment caused by the incorrect installation or servicing of the 
UPS system. 

 
1.1.4 

Make sure that the input voltage rating of the UPS matches the supply 

voltage. 

 
1.1.5 

This UPS series is intended to be install in a temperature controlled 

environment that is free of conductive contaminants. Select a location that 
will provide good air circulation for the UPS at all times. Avoid locations near 
heating devices, water or excessive humidity, or where the UPS is exposed 
to direct sunlight. Route power cords so they cannot be walked on or 
damaged. 

 
1.1.6 

To eliminate overheating of the UPS, keep all ventilation openings free 

from obstruction, and do not store anything on top of the UPS system. Keep 
the UPS system at least 12” (30 cm) away from the wall. 

 
1.1.7 

The battery will discharge naturally if the UPS is unused for any length of 

time. The batteries should be recharged every 2-3 months if unused. 

 
1.1.8 

This UPS supports electronic equipment in offices, telecommunications, 

process control, and medical applications. 

 
1.1.9 

Risk of Electrical Shock. Make sure the UPS is completely turned off when 

moving the UPS from one location to another. 

 
1.1.10  The UPS has a Maintenance Bypass Switch. Follow the procedures to 

perform the maintenance bypass operation. 

 

3

1.1.11 

SAVE THESE INSTRUCTIONS

 - This manual contains important 

instructions that should be followed during the Installation and the 
Maintenance of the UPS and batteries. 

 

1.1.12 

CAUTION

 - A disconnect switch must be provided by the user for the AC 

output circuit when the UPS’s output is hardwired. To reduce the risk of fire, 
connect only to a circuit provided with branch circuit over-current protection 
(50 amperes for 208/240V output or 90 amperes for single 120V output) in 
accordance with the National Electric Code, ANSI/NFPA 70. 

 

1.1.13 

CAUTION

 - To reduce the risk of fire, connect the input to a circuit 

provided with branch circuit over-current protection for 50 amperes in 
accordance with the National Electric Code, ANSI/NFPA 70. Use No. 6 AWG, 
60

°

C copper wire and 22.1lb-in Torque force when connecting to terminal 

block. 

 

1.1.14 

CAUTION

 - To reduce the risk of electrical shock with the installation of 

this UPS system and the connected equipment, the installer must ensure 
that the combined sum of the AC leakage current does not exceed 3.5mA. 

 

1.1.15 

WARNING

 - This Uninterruptible Power Supply (UPS) contains potentially 

hazardous voltages. Do not attempt to disassemble the UPS system 
beyond the battery replacement procedure. This UPS system contains no 
user serviceable parts. QUALIFIED SERVICE PERSONNEL ONLY must 
perform the maintenance and the battery replacement for this UPS system. 

 

1.2. 

Life Support Policy

 

 

As a general policy, we do not recommend the use of any of our products in 
life support applications where failure or malfunction of the product can be 
reasonably expected to cause failure of the life support device or to 
significantly affect its safety or effectiveness. We do not recommend the use 
of any of our products in direct patient care. We will not knowingly sell our 
products for use in such applications unless it receives in writing assurances 
satisfactory to us that (a) the risks of injury or damage have been minimized,   
(b) the customer assumes all such risks, and (c) our liability is adequately 
protected under the circumstances. 

 

1.3. 

FCC Notice 

 

This equipment has been tested and found to comply with the limits for a 
Class A computing device in accordance with the specifications in Subpart J 
of Part 15 of FCC Rules and the Class A limits for radio noise emissions from 
digital apparatus set out in the Radio Interference of the Canadian 
Department of Communications. 

Summary of Contents for Minuteman ED10000T

Page 1: ...Inc 1455 LeMay Drive Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000356 R3 ED10000T ED10200T Parallel Redundant ON LINE SERIES U...

Page 2: ...Storage instruction 12 3 4 Installation of the Castor Covers 13 3 5 Wiring the Input and Output Connections 14 3 6 Operation and Setup Instructions 19 4 Communication Port EPO Port and Option Cards 30...

Page 3: ...tteries 1 1 12 CAUTION A disconnect switch must be provided by the user for the AC output circuit when the UPS s output is hardwired To reduce the risk of fire connect only to a circuit provided with...

Page 4: ...the UPS for remote control and monitoring 2 2 4 These UPS systems can be used in a Parallel Redundant application To operate these UPS systems in the Parallel Redundant mode requires the Parallel Redu...

Page 5: ...2 Er06 Output Short Circuit 33 Er08 DC Bus high voltage level abnormal 34 Er09 DC Bus low voltage level abnormal 35 Er10 Inverter Over current 36 Er11 UPS Overheated 37 Er12 Inverter Overload 38 Er13...

Page 6: ...9 2 4 Controls and Indicators 2 4 1 UPS Control panel A LCD Display B N 1 green LED illuminates when the UPS is operating in the Parallel Redundant mode C Bypass green LED illuminates when the bypass...

Page 7: ...d by a qualified person If the package is deemed to be not usable immediately contact the freight carrier and the place of purchase USE CAUTION This UPS system is extremely heavy Always use the approp...

Page 8: ...000m 0 to 50 000 ft 3 3 Storage Instruction For extended storage with moderate climates the batteries should be charged for 12 hours every 3 months Repeat this procedure every 2 months under high temp...

Page 9: ...to the terminal blocks 3 5 1 1 1 OUTPUT connections for ED10000T Hardwired only Configurations 1 7 are for Hardwiring the output of ED10000T A Qualified Electrical Contractor must perform the hardwir...

Page 10: ...KVA max load per circuit and one 208VAC 10KVA circuit Total combined output load not to exceed 10KVA 1 Connect a jumper wire from L22 to N21 2 Circuit1 120VAC L22 Line N22 Neutral G2 Ground 3 Circuit2...

Page 11: ...to terminal G2 A Qualified Electrical Contractor must perform the hardwiring The outputs must be connected to an over current protection device circuit breaker of 50 amperes in accordance with the Nat...

Page 12: ...may be used immediately but the On Battery runtime maybe less than normally expected NOTE If the UPS is going to be out of service or stored for a prolonged period of time the batteries must be recha...

Page 13: ...ypass Input Drawing J Frequency from Utility Input Drawing K Frequency from Bypass Input Drawing L UPS Output Voltage Drawing M UPS Output Frequency Drawing N UPS Output Load Drawing O UPS Battery Vol...

Page 14: ...eck the UPS settings Drawing Q1 Buzzer audible alarm Drawing R1 Self test Drawing S1 Bypass Voltage Window Drawing T Output Frequency Synchronization Window Drawing U Inverter Output Voltage Drawing V...

Page 15: ...econds and then release the audible alarm will sound 2 beeps the LCD display screen shows as drawing Q1 then the UPS is under setting mode 3 6 5 2 Except for the Buzzer as drawing Q1 Q2 and the Self t...

Page 16: ...r on the rear panel of the Battery Pack 3 6 7 4 The UPS is OFF 3 6 7 5 To completely de energize the UPS disconnect the battery cable from the rear panel of the UPS Turn Off the utility circuit breake...

Page 17: ...on Wait for approximately 1 minute until the fans turn off then turn the input circuit breaker to the On position The UPS will be in the Bypass mode Press the On switch on the front panel for 2 beeps...

Page 18: ...er of the UPS The UPS should be unlocked but the original problem may not be resolved Call for Service 33 7 Replacing the Batteries QUALIFIED SERVICE PERSONNEL ONLY Please read all of the WARNINGS and...

Page 19: ...ining screws for the side panels on the rear panel of the UPS 7 1 9 Slide the side panels towards the rear of the UPS and lift up to remove the side panels and set aside FIG 2 FIG 1 FIG 2 35 7 1 10 Lo...

Page 20: ...37 7 1 32 Back to the right hand side of the UPS FIG 3 remove the piece of electrical tape from the end of battery positive Red wire Observer polarity Reconnect the battery positive Red wire NOTE Some...

Page 21: ...oltage let through as a percentage of an applied ANSI C62 41 Cat A 6KV 5 Noise Filter Normal and common mode EMI RFI suppression Audible Noise at 1 m 3 ft 50dB 160 280VAC at loads 50 of the rated capa...

Page 22: ...m the nearest authorized service center Replacement parts and warranty labor will be borne by Para Systems For equipment located outside of the United States and Canada Para Systems only covers faulty...

Page 23: ...Name Para Systems Inc MINUTEMAN UPS Manufacturer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No ED10000T ED10200T Year of Manufact...

Reviews: