Thank you for purchasing this power protection product.  It has been designed
and manufactured to provide many years of trouble free service.  Please read
this manual before installing your Encompass On-Line Series UPS, models
EC1000RT2U,  EC1500RT2U, EC2000RT2U, EC3000RT2U as it provides im-
portant information that should be followed during the installation and the main-
tenance of the UPS system allowing you to correctly set up your system for
the maximum safety and performance.  Included is information on customer
support and factory service, if it is required.  If you experience a problem with
the UPS system please refer to the Troubleshooting guide in this manual to
correct the problem or collect enough information so that the Technical Sup-
port Department can assist you.

SAVE THESE INSTRUCTIONS

 - This manual contains important instructions

that should be followed during the installation and the maintenance of the UPS
system and the batteries.

CAUTION!

  The maximum ambient operating temperature for this UPS series

is 40°C (“0 ~ 40°C” for Ambient Operation).

The external vents and openings on the UPS are provided for ventilation.
To ensure reliable operation of the UPS and to protect the UPS from over-
heating, these vents and openings must not be blocked or covered. Do not
insert any object into any of the vents or openings that may hinder the ve-
ntilation.

Install the UPS system in a well ventilated area, away from excess moistu-
re, heat, dust, flammable gas or explosives.

Leave adequate space (at least 20cm) in the front and at the rear of the
UPS system for proper ventilation.

Do not mount the UPS system with its front or rear panel facing down at
any angle.

 Before usage, you must allow the UPS system to adjust to room temper-

ature (20°C~25°C or 68°F~77°F) for at least one hour to avoid moisture
condensing inside the UPS.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS !

CONSIGNES DE SÉCURITÉ IMPORTANTES

SAUVEGARDEZ CES CONSIGNES!

Veuillez lire ce manuel avant l'installation de l'onduleur modèles EC1000RT2U,
EC1500RT2U, EC2000RT2U, EC3000RT2U. Il contient de l'information
importante qui doit être respectée au cours de l'installation et de l'entretien de
l'onduleur et des batteries. Cette information vous permettra de correctement
installer le système pour atteindre son rendement maximum en toute sécurité.

Chapter 1:  Introduction

WARNING:

  

Risk of Electrical Shock.  Hazardous live parts inside these

power supplies are energized from the battery even when the AC input is
disconnected.

CAUTION!

 

 To reduce the risk of electrical shock in conditions where the

load equipment grounding cannot be verified, disconnect the UPS from the
AC wall outlet before installing a computer interface cable.  Reconnect the
power cord only after all signaling connections are made.

CAUTION!  

Connect the UPS to a two pole, three wire grounded AC wall

outlet.  The receptacle must be connected to the appropriate branch protec-
tion (circuit breaker or fuse).  Connection to any other type of receptacle may
result in a shock hazard and violate local electrical codes.  Do not plug the
UPS into extension cords, adapter plugs or surge strips.

CAUTION!  

To reduce the risk of electrical shock with the installation of this

UPS equipment and the connected equipment, the user must ensure that the
combined sum of the AC leakage current does not exceed 3.5mA.

WARNING:

  

This Uninterruptible Power Supply contains potentially hazard-

ous voltages.  Do not attempt to disassemble the UPS beyond the battery
replacement procedure.  This UPS contains no user serviceable parts.  Re-
pairs and battery replacement must be performed by

 QUALIFIED SERVICE

PERSONNEL ONLY.

CAUTION!

  To reduce the risk of fire, connect only to a utility powered

circuit provided with 20 / 30 amperes maximum branch circuit over-current
protection in accordance with the National Electric Code, ANSI/NFPA 70.

WARNING:  Qualified Service Personnel ONLY 

must perform the Installa-

tion and Servicing of these UPS systems.  MINUTEMAN accepts no liabilities
and is not limited to: injury to the Service Personnel, or damages to; the UPS,
or the connected equipment caused by the incorrect installation or servicing
of the UPS system.

CAUTION!

  This UPS series is 

ONLY

 intended to be installed in an indoor

temperature controlled environment that is free of conductive contaminants.
This UPS series is not intended for use in a computer room as defined in the
Standard for the Protection of Electronic Computer/Data Processing Equip-
ment ANSI/NFPA 75.

NOTE:

  These UPSs are shipped with the batteries disconnected.  The batter-

ies must be connected before putting these UPSs into service.  Refer to Sec-
tion 3 "Installation" for connecting the batteries.

CAUTION!  

DO NOT USE THE MOUNTING BRACKETS TO LIFT THE

UPS.

  The mounting brackets are 

ONLY

 for securing the UPS to the rack.

Summary of Contents for Minuteman On-Line RT Series

Page 1: ...ser s Manual Encompass RT On Line UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000519 R...

Page 2: ...6 3 Installation 9 4 Operation 14 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...ement maximum en toute s curit Chapter 1 Introduction WARNING Risk of Electrical Shock Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconn...

Page 4: ...AC wall outlet 3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where...

Page 5: ...od 8 The LCD displays the status of the UPS 9 Pressing the Enter button saves the changes made to the UPS settings 10 Pressing the Page Up button goes to the previous page or will change the UPS setti...

Page 6: ...utility power 6 The option slot is for option cords 7 The Battery Backup output receptacles The output receptacles are electrically wired into two segments to support the Load Shedding Function Labele...

Page 7: ...RSONNELONLY Please read all of the WARNINGS and CAUTIONS before attempting to con nect the batteries WARNING Use two or more people when installing the UPS the UPS is extremely heavy 1 Remove the UPS...

Page 8: ...r hours every ninety days CHECKING THE SITE WIRING FAULT After plugging the UPS into the AC wall outlet check the Site Wiring Fault icon on the front panel of the UPS If the Site Wiring Fault icon is...

Page 9: ...ge condition occurs the UPS will transfer to the battery mode the inverter will turn on powering the connected equipment the On Battery indicator will illuminate and the audible alarm will sound once...

Page 10: ...re Once the Economy mode has been Enabled the LCD will display ECO and the Bypass Yellow LED will be illuminate Turn on the connected equipment one at a time OPTION SLOT The option slot on the rear pa...

Page 11: ...When the UPS detects a hardware and or internal fault the Fault icon will illuminate and the audible alarm will beep continuously The fault condition in some instances may be reset by turning the UPS...

Page 12: ...the UPS press the On but ton If UPS works normally the software has control of the UPS Charge the batteries for 8 hours and retest If the runtime is still less than expected the batteries may need to...

Page 13: ...onment and human health if not disposed of properly Refer to local codes for proper disposal requirements or return the battery to the supplier CAUTION The battery system can present a risk of electri...

Page 14: ...e Frequency 50 60Hz 0 2Hz unless synchronized to utility Nominal Voltage Adjustable Maximum Power Capacity 0 ms Typical 89 Full Load Resettable Circuit Breaker 50 or 60 Hz 6Hz autosensing 0 160VAC 55V...

Page 15: ...equipment located outside of the United States and Canada Para Systems only covers faulty parts Para Systems products that are depot repaired or replaced pursuant to this warranty shall only be warra...

Page 16: ...C1000RT2U Y EC1500RT2U Y EC2000RT2U Y EC3000RT2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date July 10 2017 Robert Calhoun Nam...

Reviews: