48
A2.1 Troubleshooting Static IP Issues
To troubleshoot Static IP issues:
1.
Open BabyWare.
2.
Navigate to the
Programming
window
(see Configuring Server Settings on page 25).
3.
Select the
Communication Settings
tab.
The Communication Settings tab opens.
4.
Select the
IP/Static
radio button.
5.
Locate the IP device:
a.
Select the
Locate
icon .
Figure 2 – Programming Window
The Located IP device on Network window opens.
Figure 3 – Locate IP Device on Network Window
b.
Locate the IP address that matches the Default Gateway.
c.
Confirm that the Port # matches the port number assigned in the router port forwarding.
6.
Ensure that the router is correctly connected according to the router manufacturer instructions.
7.
Configure IP/Static configurations for the HD77 camera:
a.
Un-check the DHCP Enabled box in the TCP/IP pane of the Programming window (see
Figure
3.2
on page 20.
b.
Locate the IP Device - see step 5 above.
c.
Record the IP Address, Port, MAC address and Serial number values.
d.
Select
Configure
.
Summary of Contents for HD77