background image

1640 Icon LCD Keypad 19

4.0 Additional Features

4.1 Programming Chime Zones

A Chime Enabled zone will advise you every time it is opened 
by causing your keypad to beep. 

 

Each keypad must be Chimed separately. 

4.2 Keypad Muting

When muted, the keypad will only emit the confirmation beep, 
rejection beep, and beep when a key is pressed. Therefore, 
when muted, the keypad will not beep during an alarm or 
during the exit delay. Press and hold the 

 key for 3 seconds 

to enable or disable Keypad Muting. If the keypad emits a 
confirmation beep, Keypad Muting is enabled for that keypad. 
If the keypad emits a rejection beep, the feature is disabled.

How do I Chime Zones?

1. Press & hold the 

[9]

 key for 3 seconds. 

2. Enter the two-digit zone number of the desired zone or 

use the 

[

U

]

 or 

[

V

]

 buttons to scroll to the desired zone 

and press the 

 

key. Repeat to unchime the zone. If the 

zone number illuminates, the zone is chimed. If the zone 
number is extinguished, the zone is unchimed. To 
remove chiming from all zones, press the 

 

key. 

3. Press the 

 key to exit.

1640-EU02.fm  Page 19  Wednesday, May 18, 2005  3:10 PM

Summary of Contents for 1640

Page 1: ...Icon LCD Keypad 1640 User Guide...

Page 2: ......

Page 3: ...6 Arming Disarming 7 Exit Delay 7 Disarming Deactivating an Alarm 7 Alarm Memory Display 8 Regular Arming 8 Stay Arming 9 Instant Arming 9 Force Arming 10 Manual Bypass Programming 11 One Touch Arming...

Page 4: ...21 Quick Function Keys 21 Keypad Settings 22 Partitioning 22 Testing Maintenance 23 Programming Access Codes 24 System Master Code Default 123456 24 Master Codes 24 Duress Code 25 Programming Access...

Page 5: ...l be executed and displayed through the keypad Your security system uses advanced technology which will provide you with reliable security protection and powerful features that are easy to use Since y...

Page 6: ...he action will be cancelled 2 1 Action Keys The 1640 has action keys with which you can access its various functions as shown in Table 1 Table 1 Action Keys Name Key Description Stay Arm Refer to Stay...

Page 7: ...in Table 2 Table 2 Indicator Lights Events in Memory Refer to Alarm Memory Display on page 8 System Trouble Refer to Trouble List on page 27 N A Reserved for future use LED Name Status Description AC...

Page 8: ...flash System in alarm Red and yellow flash alternately Communication bus fault Icon s Description Indicates numbers corresponding to zones or option numbers Numbers will illuminate to indicate that a...

Page 9: ...codes Indicates which zone is in Chime Mode Refer to Programming Chime Zones on page 19 Indicates zones in tamper Refer to Arming Disarming on page 7 Indicates zones that are in Fire Alarm Refer to Fi...

Page 10: ...eep When an operation i e arming disarming is successfully entered on the keypad or when the system switches to a new status mode the keypad produces an intermittent beep tone BEEP BEEP BEEP BEEP Reje...

Page 11: ...e system arms The keypad may beep during the Exit Delay and the icon will flash with the number of the partition in exit delay 3 2 Disarming Deactivating an Alarm To disarm an armed system or an alarm...

Page 12: ...ng Auto Arming see page 14 a Keyswitch see page 14 or One Touch Arming see page 12 How Do I View the Alarm Menu 1 Press the key 2 The icon will flash and the corresponding number of zones that were in...

Page 13: ...ge 14 or One Touch Arming see page 12 3 6 Instant Arming Instant Arming is similar to Stay Arming Instant Arming partially arms your system and enables you to remain in the perimeter after the system...

Page 14: ...otecting the area occupied by a keypad Force Arming can also be activated by using One Touch Force Arming see page 13 How Do I Instant Arm 1 Stay Arm the system as outlined in Stay Arming on page 9 2...

Page 15: ...After disarming the system the bypass entries are erased The Bypass Recall Feature reinstates the previous bypass How Do I Bypass Zones 1 Press the key 2 Enter your ACCESS CODE The icon flashes 3 If r...

Page 16: ...y for 3 seconds to arm all zones in the area You can use this feature to allow specific individuals like service personnel i e cleaners to arm without giving them access to any other alarm system oper...

Page 17: ...eave the premises When the Exit Delay elapses the system will switch to Regular Arming see page 8 3 9 5 Exit and Force Arm With the system is already stay armed press and hold the key for 3 seconds to...

Page 18: ...omentary Keyswitch set the keyswitch to the ON position then turn it back to the OFF position Repeating this sequence will disarm the system 3 11 Timed Auto Arming You can program the time at which yo...

Page 19: ...ree squawks at 2 second intervals until silenced or reset by entering a valid access code If the zone is a Delayed Fire Zone there is a delay before the system contacts the monitoring station This wil...

Page 20: ...16 User Guide Figure 3 1 Delayed Fire Zone Event Sequence...

Page 21: ...problem in single family homes than in apartments since the heating systems in single family homes are often not professionally maintained Fire Safety Tips In the event of a fire escape first then cal...

Page 22: ...t Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors should be installed outside each separate sleeping area in the immediate vicini...

Page 23: ...delay Press and hold the key for 3 seconds to enable or disable Keypad Muting If the keypad emits a confirmation beep Keypad Muting is enabled for that keypad If the keypad emits a rejection beep the...

Page 24: ...imultaneously pressing and holding two specific buttons for three seconds Based on your needs these panic alarms can generate audible alarms sirens or bells or silent alarms and can communicate specif...

Page 25: ...eport code to the monitoring station 4 5 2 Call PC Press the key enter your MASTER CODE and press the key This will initiate a call to the monitoring station that is using the WinLoad software How do...

Page 26: ...ettings You can modify the keypad s setting to suit your needs 4 7 Partitioning Your Spectra system is equipped with a partitioning feature that can divide your alarm system into two distinct areas id...

Page 27: ...d features will be recognized as belonging to Area 1 4 8 Testing Maintenance With the system disarmed and the light is ON activate motion detectors by walking in the protected area Open and close prot...

Page 28: ...s For information on how each access code can arm or disarm the system refer to the System Checklist on page 31 5 1 System Master Code Default 123456 The System Master Code can arm or disarm any area...

Page 29: ...Master Code can modify or delete user access codes assigned to both areas 5 3 Duress Code If you are forced to arm or disarm your system entering the access code assigned to User 048 will arm or disa...

Page 30: ...er a new 4 or 6 digit ACCESS CODE 5 Press to exit How Do I Delete Access Codes 1 Repeat steps 1 to 3 see above 2 Press the key once for each digit in the access code 4 or 6 times until the keypad emit...

Page 31: ...ondition has occurred Press the key to stop the trouble beep When a trouble condition occurs the icon will illuminate 1 No or Low Battery Trouble The backup battery is disconnected or the battery volt...

Page 32: ...fuseless circuit will automatically shut down if the current exceeds a predetermined value When the system is disarmed the current is cut from the bell output and the trouble warning may extinguish b...

Page 33: ...ress the 9 key to view which zones are affected After pressing the 9 key the 1640 will display the and icons with the corresponding number of the zone s in tamper The and icons will extinguish once th...

Page 34: ...t If for any reason your keypad is no longer communicating with your alarm system the keypad will emit three consecutive beeps at 3 second intervals When communication is restored the keypad will resu...

Page 35: ...__ ____ N N N N N 02 _______________ Keyswitch Y N N N Type _____________ ____ N N N N N 03 _______________ Fire Zone Y N N N Delayed Y N N N ____ N N N N N 04 _______________ ____ N N N N N 05 ______...

Page 36: ...Area 1 or 2 Byp Stay Force Arm Only 001 ___________________ System Master Code 123456 1 2 on on on 002 ___________________ Master Code 1 ____ N N N N 003 ___________________ Master Code 2 ____ N N N N...

Page 37: ...____ N N N N 018 ___________________ ____ N N N N 019 ___________________ ____ N N N N 020 ___________________ ____ N N N N 021 ___________________ ____ N N N N 022 ___________________ ____ N N N N 02...

Page 38: ..._____ ____ N N N N 038 ___________________ ____ N N N N 039 ___________________ ____ N N N N 040 ___________________ ____ N N N N 041 ___________________ ____ N N N N 042 ___________________ ____ N N...

Page 39: ...ay 1 Area 1 _______sec time to exit site Exit Delay 2 Area 2 _______sec time to exit site Entry Delay 1 _______sec time to disarm before alarm enter through zone ___________ Entry Delay 2 _______sec t...

Page 40: ...the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen...

Page 41: ...Notes...

Page 42: ......

Page 43: ......

Page 44: ...780 Industriel Blvd St Eustache QC Canada J7R 5V3 Tel 450 491 7444 Fax 450 491 2313 www paradox ca Printed in Canada 05 2005 1640 EU02...

Reviews: