background image

 

 

 

     

 

 

 

 

DB7 Quick Installation with BlueEye application 

 

 

 

Locating the DB7 

Mount the DB7 near the door to be monitored. Use the angle bracket (purchased separately) if needed  

to better supervise the area. 

 

 

Powering the DB7 

 

*ALLOW 8 hours of charging before full function may be available*

 

 

Connect the two power wires (recommend 18 gauge up to 30 meters) to the DB7. A wide power 

supply voltage range can be used (12-24 volts AC or DC, minimum 10W power supply). The DB7 

must be able to consume 500 mA and 10 volts at the DB7 connection terminals over the supplied 

wires. Make sure the wires and length support this power. Connecting to Aux bus wires of the  

alarm system may not be able to supply the current needed, especially 21-gauge wires or enough 

Aux reserve. 

 

 

Power Supply 

When connecting the DB7 for the first time to power, the battery must be charged at least 60%, 

otherwise, not all functions may be available and the DB7 might shut down. Usually, normal 

operation can be resumed when the battery is over 60% when connected the first time.  

Usually, with a proper power supply, the DB7 will be ready to test use after one hour of charging  

or out of the box. Battery indication will be available in the application after about 10 minutes. 

 

 

Using Existing Doorbell Wires 

Existing doorbell wires can be used, but 

DO NOT

 connect the DB7 in series with previously installed 

bell(s). The DB7 may NOT function after the battery will be drained out due to weak power supply. 

 

 

 