24 Installer’s Guide
partition, only Partition 2 will arm.
Option
[5]
ON = door assigned to Partition 1(default)
Option
[6]
ON = door assigned to Partition 2
Option
[7]
ON = door assigned to Partition 3
Option
[8]
ON = door assigned to Partition 4
OFF
= Access Control Cards will not be able to arm and/or
disarm partitions from the door's reader.
6.3 R
EADER
’
S
O
PTIONS
6.3.1 Reader’s LED To Follow Partition’s Status
Section [002]: Option [6]
The reader's LED can be programmed to flash according to the
partition's status. When this feature is enabled, the reader’s red
LED will flash when the partition is arming, in Exit Delay, in Entry
Delay, in Burglar Alarm or in Fire Alarm.
Option
[6]
ON = LED follows the door’s partition status. (default)
Option
[6]
OFF= The reader's LED will not flash.
6.3.2 Reader’s Beep To Follow Partition's Status
Section [002]: Option [7]
This feature will only function when section
[002]
option
[6]
is
enabled. The reader can be programmed to beep according to its
keypad's beep when the partition assigned to the door is arming,
in Exit Delay, in Entry Delay, in Burglar Alarm, or in Fire Alarm.
Option
[7]
ON = Beep follows the partition's status. (default)
Option
[7]
OFF= The beep will not follow the partition's status.
Summary of Contents for Digiplex DGP-641
Page 2: ......
Page 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...
Page 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...
Page 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...
Page 42: ......
Page 43: ......
Page 44: ......