Digiplex DGP-848
- 41 -
Programming Guide
and
[049]
to
[056]
(Keyswitch serial numbers), enter installer programming mode, then enter section
[965]
.
To copy the contents to the Memory Key
including
sections
[001]
to
[048]
and
[049]
to
[056]
, enter section
[966]
.
5.
After the confirmation beep,
wait 10 seconds
and remove the Memory Key. Remove the Memory Key’s jumper if you do
not wish to accidentally overwrite its contents
.
Software Reset
Performing a software reset will set certain parameters to default values. To do so:
1.
Make sure the
RESET
jumper on the control panel is on.
2.
Enter Programming Mode (see page 1).
3.
Enter the 3-digit
[
SECTION
]
corresponding to the software reset you wish to perform:
Installer Quick Function Keys
To access the installer functions, press and hold the
[0]
key, enter the
[
INSTALLER
CODE
]
, and then:
For LCD keypads
: press the key indicated in the list below that corresponds to the function you wish to activate.
For Grafica keypads
: press the center action key (
Options
), highlight the desired function and then press the left action key
(
Select
).
Section #
Description
[970]
Entering this section will reset all programmable sections from
[001]
to
[896]
(except sections
[451]
to
[498]
,
[555]
,
[556]
,
[560]
,
[790]
to
[795]
, and
[800]
) to default values. The Zone Labels, Panel ID, PC Password, PC
Telephone Number, Installer Code, System Master Code, Event Buffer, and Automatic Report Codes will not
be reset.
[974]
Entering this section resets the following Access Control sections:
[301]
to
[332]
,
[340]
to
[355]
,
[361]
to
[375]
,
[381]
to
[392]
, and
[537]
.
[975]
Entering this section will reset all Zone and Keyswitch programming sections from
[001]
to
[056]
, and
[101]
to
[156]
to default values.
[976]
Entering this section will reset the following sections to default values:
[200]
to
[261]
,
[270]
to
[274]
,
[400]
to
[409]
, and
[440]
to
[442]
.
[977]
Entering this section will reset sections from
[500]
to
[522]
to default values.
[978]
Entering this section will reset the following communication sections to default values:
[521]
to
[536]
,
[550]
to
[554]
,
[561]
to
[564]
, and
[600]
to
[718]
.
[979]
Entering this section will reset all user code sections from
[801]
to
[896]
to default values.
Section #
Data
Description
Default
[990]
___/___/___ (147=lock, 000=unlock)
LOCK
INSTALLER
CODE
000
[
STAY
]
Test Report:
Sends the “Test Report” report code programmed in section
[717]
to the monitoring station.
[
FORCE
]
Call WinLoad Software:
Will dial the PC telephone number programmed in section
[560]
in order to initiate
communication with a computer using the WinLoad Upload/Download software.
[
ARM
]
Answer WinLoad Software:
Will force the control panel to answer a call made by the monitoring station that is
using the WinLoad upload/download software.
[
DISARM
]
Cancel Communication:
Cancels all communication with the WinLoad Software or with the monitoring station
until the next reportable event.
[
MEM
]
Installer Test Mode:
The installer test mode will allow you to perform walk tests where the bell or siren will
squawk to indicate opened zones. Press [
MEM
] again to exit. Partitions can not be armed if the Installer Test
Mode is enabled.
[
TRBL
]
Start Module Scan:
The keypad will display the serial number of each module on the bus.
[
ACC
]
For LCD Keypads (DGP2-641) only
Combus Voltmeter
: Verify if the combus is supplying sufficient power. A reading of 12.3V indicates that the
voltage is too low. The voltage may drop during the control panel battery test.