DigiplexNE DGP-NE96
- 30 -
Programming Guide
= Default setting
Dialer Options
= Default setting
SECTION [3032] : Partition Options 2
SECTION [3033] : System Options 2
Option
OFF
ON
Option
OFF
ON
[1]
Bell/siren output in partition 1
N
Disabled
Enabled
[1]
Multiple actions in user menu
Disabled
N
Enabled
[2]
Bell/siren output in partition 2
Disabled
N
Enabled
[2]
User code length
Fixed
N
Flexible
[3]
Bell/siren output in partition 3
Disabled
N
Enabled
[3]
User code length (if option
[2]
OFF)
4-digits
N
6-digits
[4]
Bell/siren output in partition 4
Disabled
N
Enabled
[4]
Power save mode
N
Disabled
Enabled
[5]
Bell/siren output in partition 5
Disabled
N
Enabled
[5]
Bypass not displayed while system
is armed
N
Disabled
Enabled
[6]
Bell/siren output in partition 6
Disabled
N
Enabled
[6]
Trouble Latch
Disabled
N
Enabled
[7]
Bell/siren output in partition 7
Disabled
N
Enabled
[7]
EOL resistor on hardwire zones
Disabled
N
Enabled
[8]
Bell/siren output in partition 8
Disabled
N
Enabled
[8]
(ATZ) Zone Doubling
Disabled
N
Enabled
SECTION [3034] : System Options 3
SECTION [3035] : Restrict Arming Options
Option
OFF
ON
Option
OFF
ON
[1]&[2]
Wireless Transmitter Supervision
Options (see table below)
N
See Table
N
See Table
N
See Table
N
See Table
[1]
Restrict arming on AC failure
Disabled
N
Enabled
[2]
Restrict arming on battery failure
Disabled
N
Enabled
[3]
Generate supervision failure if
detected on a bypassed wireless zone
Yes
N
No
[3]
Restrict arming on bell or auxiliary
failure
Disabled
N
Enabled
[4]
Restrict arming on a wireless
transmitter supervision failure
Disabled
N
Enabled
[4]
Restrict arming on TLM failure
Disabled
N
Enabled
[5]&[6]
Zone & Module Tamper Recognition
Options (see table below)
N
See Table
N
See Table
N
See Table
N
See Table
[5]
Restrict arming on module troubles
Disabled
N
Enabled
[6]
Future Use
N
N/A
N
N/A
[7]
Generate tamper if detected on
bypass zone
N
Yes
No
[7]
Transmit zone status on serial port
Disabled
N
Enabled
[8]
Restrict arming on tamper trouble
Disabled
N
Enabled
[8]
Serial Port Baud Rate
19,200
N
38,400
Wireless Transmitter Supervision Options
(Section [3034]; options
[1]
&
[2]
)
Zone & Module Tamper Recognition Options
(Section [3034]
:
options
[5]
&
[6]
)
[1]
[2]
[5]
[6]
OFF
OFF
-
Disabled
(default)
OFF OFF
-
Disabled
(default)
ON
OFF
- When disarmed:
GENERATES
TROUBLE
ONLY
ON
OFF - When disarmed:
GE NE RATE S
TROUBLE
ONLY
- When armed: Follows
Zone Alarm Types
(page 7)
- When armed: Follows
Zone Alarm Types
(page 7)
OFF
ON
- When disarmed:
GENERATES
SILE NT
A LARM
OFF ON - When disarmed:
GE NE RATE S
SILENT
ALARM
- When armed: Follows
Zone Alarm Types
(page 7)
- When armed: Follows
Zone Alarm Types
(page 7)
ON
ON
- When disarmed:
GENERATES
AUDIBLE
A LARM
ON
ON - When disarmed:
GE NE RATE S
AUDIB LE
ALARM
- When armed: Follows
Zone Alarm Types
(page 7)
- When armed: Follows
Zone Alarm Types
(page 7)
SECTION [3036]: Dialer Options 1
SECTION [3037] : Dialer Options 2
Option
OFF
ON
Option
OFF
ON
[1]&[2]
Telephone Line Monitoring (TLM) -
(see table on page 29)
N
See Table
N
See Table
N
See Table
N
See Table
[1]
Call back
Disabled
N
Enabled
[2]
Automatic event buffer transmission
Disabled
N
Enabled
[3]
Dialer (reporting to monitoring
station)
Disabled
N
Enabled
[3]&[4]
Hourly test transmission (see table
on page 29)
N
See Table
N
See Table
N
See Table
N
See Table
[4]
Dialing method
N
Pulse
Tone
(DTMF)
[5]
Pulse ratio
(E.U. = Europe; N.A. = North America)
N
1:2
(E.U.)
1:1.5
(N.A.)
[5]
Keypad beep on successful arming/
disarming report
Disabled
N
Enabled
[6]
Busy tone detection
N
Disabled
Enabled
[6]
Alternate Dialing
Disabled
N
Enabled
[7]
Switch to pulse dialing on 5
th
attempt
Disabled
N
Enabled
[7]
Dial Tone Delay (if no dial tone)
Force dial
N
Hang-up
[8]
Bell/siren upon communication
failure if system is armed
Disabled
N
Enabled
[8]
Report zone restore
ON =
On zone closure;
OFF =
On bell cut-off
Disabled
N
Enabled